Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Cleaning And Maintenance - Omnitronic Variable Distance Tube Benutzerhandbuch

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Installation

Caution: The loads have to be installed in a balanced way.
Caution: The carrying capacity of the stand must never exceed 18 kg!
Installation of speakers with flange connector
Carefully install the tube onto a speaker box having an appropriate flange connector.
Carefully install a second speaker box (max. 18 kg) with the appropriate flange connector on the top of the
tube.
Loosen the fixation screw of the telescopic tube. Carefully pull out the telescopic tube to the desired height.
Please ensure, that the bore-hole for the safety bolt is always located directly above the stand tube stop.
Important!! The maximum extension height should never be exceeded.
Tighten the fixation screw. Insert the safety bolt as a secondary securing into the bore-hole of the telescopic
tube.
Before taking into operation for the first time, the installation has to be approved by an expert!

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
1) The following points have to be considered during the inspection:
2) The standing stability of the stand has to be checked.
3) All carrying parts have to be inspected on damages or material fatigue.
4) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
5) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
6) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
7) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
Maintenance and service operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
DANGER TO LIFE!