INSTALLATION MANUAL
- Insert the power supply cable (A) into the hole and then install the light,
applying light pressure until it is completely fitted as illustrated in figure 2.
FLUSH INSTALLATION ON METAL SURFACES
ORBIT ML devices can be flush mounted on 0.7 mm thick (min.) metal
surfaces and on a ø 68 mm hole as illustrated in figure 3.
- The light must be anchored to the metallic bracket by inserting first one
spring and then the other, applying slight pressure until completely fitted
as illustrated in figure 4.
CONNECTION OF THE SMALLY-CUBIT-QUADRUM Plus (Plug & Play)
POWER CABLE
ORBIT Plus (Plug & Play) models refer to the configurations of the devices
that have a built-in disconnectable power cable. ORBIT Plus power lead can
be disconnected and allows the device to be easily disconnected and
removed if necessary. Follow the installation instructions for connection of
the cable to the device.
- For connection of the power cable to the device, insert the cable
connector (B) into the slot (C) on the device, until the safety hook (D) is
press-fitted into place as illustrated in figure 5.
- To remove the device power cable, press the safety release (D) slightly
with your finger and extract the connector (B) from the slot (C) on the
device as illustrated in figure 5.
EN
SURFACE INSTALLATION
All ORBIT models can be surface mounted with the aid of specific supports.
The installation can be carried out with the light power supply cable in both
an axial or radial position with respect to the installation surface. In the
event of a specific requirement a power wire exit hole can nevertheless be
drilled in other positions as long as it does not compromise the integrity of
the wire and/or the connector installed on it.
- Secure the plastic bracket (E) to the installation surface with the included
screws (F); insert the light (G) into the plastic support, applying light
pressure until it is completely fitted as illustrated in figure 6 orienting it in
the desired position and making sure that the springs (H) are not located
at the spacers (I).
- If necessary, bore a ø ≥ 8mm exit hole for the power supply cable as
illustrated in figure 7.
CONNECTING THE DEVICE TO THE POWER SUPPLY _ static light
configuration
- Connect ORBIT only to a safe power supply with 12Vdc stabilised voltage
(sold separately) and with power at least 10% higher than the total load.
For the total load calculation check plate data printed on the product
label.