Security Note
If the lubricator is started without opening the outlet or in case of blocked grease lines
within the installation, the pressure in the lubricator can build up approx. 5 bar. At an
overpressure of approx. 6 bar, the dispenser detaches from the connector. The pressu-
re behind the piston is released and grease or oil can escape from the dispenser.
Warning: For applications in an environment with an explosive
atmosphere, there is a risk of electrostatic discharges or of propagating
brush discharges on the surface of the lubricator. Suitable precaution-
ary measures must be taken to minimise the risk. To avoid electrostatic
charging during cleaning, only clean the lubricator with a damp cloth.
Do not expose the lubricator to any air flow that may result in electrostatic
charging of the lubricator.
The correct functioning of the lubricator can only be assured if recommended lubricants
and original simalube accessories are used, and if the installation, operating and
maintenance instructions are closely followed. The manufacturer cannot accept any
responsibility for damages as a result of ignoring the instructions mentioned above.
Important: Before putting simalube multipoint into operation, fill extensions and the
lubrication lines with the appropriate simalube greases using a grease gun. Use only
original accessories.
The simalube multipoint has the following approvals:
II 1 G
II 1 D
I M1
Power generation: Hydrogen gas producing drycell
Operating temperature: –20 ° C to +55 ° C (–4 ° F to +131 ° F) ambient temperature
Ex ia IIC T6 Ga
Ex ia IIIC T
80 ° C Da
200
Ex ia I Ma
9