Herunterladen Diese Seite drucken

Elreha TAA 2140 Betriebsanleitung Seite 2

Universalanzeige
Vorschau ausblenden Andere Handbücher für TAA 2140:

Werbung

Page 2
Parameterliste
Nr.
Parameter
P01 .... Istwert 0-10V-Eingang (F1) . ................... -50...300 . ................................................................................................................nur Anzeige
P02 .... Istwert 4-20mA-Eingang (F2) . ................ -50...300 . ................................................................................................................nur Anzeige
P03 .... Anzeigemodus ....................................... 0= ohne Nachkommastelle mit Störungsfilter ........................................................2
P04 .... Display Modus ....................................... 0= normale Anzeige ...............................................................................................0
P05 .... Anzeige bei 10V an Signaleingang 1 . .... -50...300 . ................................................................................................................100
P06 .... Anzeige bei 0V an Signaleingang 1 . ...... -50...300 . ................................................................................................................-50
P07 .... Anzeige bei 20mA an Sign.eingang 2 . ... -50...300 . ................................................................................................................100
P08 .... Anzeige bei 4mA an Sign.eingang 2 . ..... -50...300 . ................................................................................................................0
P09 .... Korrekturwert Eingang F1 . ..................... ± 10.0 .....................................................................................................................0
P10 .... Korrekturwert Eingang F2 . ..................... -10,1...+10.0 (Mit -10.1 ist dieser Fühler abgeschaltet, Anzeige wechselt . ...........0
P11 .... Alarm-Obergrenze Eingang F1 . ............. -50...+300°C . ..........................................................................................................+300
P12 .... Alarm-Untergrenze Eingang F1 ............. -50...P07 ................................................................................................................-50
P13 .... Alarm-Obergrenze Eingang F2 . ............. -50...+300°C . ..........................................................................................................+300
P14 .... Alarm-Untergrenze Eingang F2 ............. -50...P09 ................................................................................................................-50
P15 .... Alarmverzögerung ................................. 1...99 Minuten ........................................................................................................60 Minuten
P16 .... Alarmquittierungszeit ............................. 0...99 Minuten (0=keine Alarmwiederholung nach Quittierung) .............................15 Minuten
P17 .... Restlaufzeit Alarm/Quittierung ...............................................................................................................................................Nur Anzeige
P18 .... Zugangscode ......................................... 88 ...........................................................................................................................00
Parameters
No.
Parameter
P01 .... Actual value signal input 1 ..................... -50...300 . ................................................................................................................display only
P02 .... Actual value signal input 2 ..................... -50...300 . ................................................................................................................display only
P03 .... Display Mode ......................................... 0= without decimal place, with noise filter . .............................................................2
P04 .... Alternating Mode . ................................... 0= not alternating ...................................................................................................0
P05 .... Display with 10V at signal input 1 ......... -50...300 . ................................................................................................................100
P06 .... Display with 0V at signal input 1 ............ -50...300 . ................................................................................................................-50
P07 .... Display with 20mA at signal input 2 ....... -50...300 . ................................................................................................................100
P08 .... Display with 4mA at signal input 2 ......... -50...300 . ................................................................................................................0
P09 .... Correction value for signal input 1 ......... ± 10.0 .....................................................................................................................0
P10 .... Correction value for signal input 2 ......... -10,1...+10.0 (With -10.1, this input is switched off, P02 changes to "oFF") ..........0
P11 .... Alarm upper limit signal of input 1 . ......... -50...+300°C . ..........................................................................................................+300
P12 .... Alarm lower limit signal of input 1 .......... -50...P07 ................................................................................................................-50
P13 .... Alarm upper limit signal of input 2 . ......... -50...+300°C . ..........................................................................................................+300
P14 .... Alarm lower limit signal of input 2 .......... -50...P09 ................................................................................................................-50
P15 .... Alarm delay . ........................................... 1...99 minutes ........................................................................................................60 minutes
P16 .... Alarm repetition time . ............................. 0...99 minutes (0 = no alarm repetition after a reset) . ............................................15 minutes
P17 .... Remaining time Alarm/Reset .................................................................................................................................................display only
P18 .... Access Code . ......................................... 88 ...........................................................................................................................00
Liste des paramètres
Nr.
Paramètre
P01 .... Mesure entrée 1 . .................................... -50...300 . ................................................................................................................--
P02 .... Mesure entrée 2 . .................................... -50...300 . ................................................................................................................--
P03 .... Mode d'affichage . ................................... 0= sans 0.1 avec filtrage . .......................................................................................2
P04 .... Mode display . ......................................... 0= Affichage normal ...............................................................................................0
P05 .... Affichage entrée 1 pour 10V .................. -50...300 . ................................................................................................................100
P06 .... Affichage entrée 1 pour 0V .................... -50...300 . ................................................................................................................-50
P07 .... Affichage entrée 2 pour 20mA ............... -50...300 . ................................................................................................................100
P08 .... Affichage entrée 2 pour 4mA ................. -50...300 . ................................................................................................................0
P09 .... Correction mesure entrée 1 ................... ± 10.0 .....................................................................................................................0
P10 .... Correction mesure entrée 2 ................... -10,1...+10.0 (en réglant jusqu'à -10.1, l'afficheur . .................................................0
P11 .... Seuil haut alarme entrée 1 . .................... -50...+300°C . ..........................................................................................................+300
P12 .... Seuil bas alarme entrée 1 . ..................... -50...P07 ................................................................................................................-50
P13 .... Seuil haut alarme entrée 2 . .................... -50...+300°C . ..........................................................................................................+300
P14 .... Seuil bas alarme entrée 2 . ..................... -50...P09 ................................................................................................................-50
P15 .... Retard d'alarme ..................................... 1...99 minutes ........................................................................................................60 minutes
P16 .... Temps avant répétition alarme . .............. 0...99 minutes (0=pas de répétition alarme après acquittement) . ..........................15 minutes
P17 .... Temps restant avant alarme .................. affichage seul.
P18 .... Entrée code de déverrouillage . .............. 88 ...........................................................................................................................00
We state the following: When operated in accordance with the technical manual, the criteria have been met that are outlined in the guidelines of the
council for alignment of statutory orders of the member states on EMC-Directive (2004/108/EC) and the Low Voltage Directive (LVD 2006/95/EC).
This declarations are valid for those products covered by the technical manual which itself is part of the declaration. To meet the requirements, the
currently valid versions of the relevant standards have been used
This statement is made from the manufacturer / importer
ELREHA Elektronische Regelungen GmbH
D-68766 Hockenheim
www.elreha.de
(Name / Anschrift / name / adress)
original set up: 14.4.09, tkd/jr
Bereich
1= mit Nachkommastelle und Störungsfilter
2= mit Nachkommastelle ohne Störungsfilter
1= alle 16 Sekunden wird von P01-Anzeige auf P02-Anzeige gewechselt.
Dazu wird jeweils kurz die Parameternummer eingeblendet.
dann auf "oFF")
Range
1= with decimal place and noise filter
2= with decimal place, without noise filter
1= every 16 seconds the display changes from P01 to P02. In doing so,
the parameter number appears always for a short time
Plage
1= avec 0.1 avec filtrage
2= avec 0.1 sans filtrage
1= toutes les 16 secondes, l'afficheur permute entre P01 et P02, pour
visualiser 2 mesures en même temps
indique "oFF" et l'entrée est inhibée)
EG-Statement of Conformity
checked: 15.4.09, ek/ha
approved: 15.4.09, mkt/sha
by:
Werner Roemer, Technischer Leiter, Technical Director
Hockenheim
15.04.2009
.............
Ort/city
Datum/date
transl.(E):
TAA 2140, TAA 22140
Werkseinst.
Factory set
Val. usine
.......................................................
Unterschrift/sign
korr: 3.9.15, tkd/jr

Werbung

loading

Diese Anleitung auch für:

Taa 22140