Installation or removal
Detailed information about the different
ways of installing or removing the radia-
tor heating element are available from the
manufacturer or importer (see footnotes at
the end of the manual). Below we list some
basic requirements and principles which
must be followed to ensure long term re-
liable operation.
To ensure safe operation, the power rat-
ing of the heating element should always
be lower than that of the radiator for
75/65/20°  C parameters. We recommend-
ed to select heating element with the pow-
er output around 80% to a maximum of
100% of the radiator output the heating el-
ement is to be installed in.
EN
Before installation or first use:
1. Read the chapter Safety requirements
—Installation.
2. Fit the heating element using the cor-
rect spanner (size
3. The heating element must be installed
at the bottom of the radiator, perpen-
dicular to the radiator pipes, preserving
space for proper circulation of the heat-
ing medium.
4. Use a suitable heating medium for fill-
ing the electric radiator (water, special
products based on water and glycol for
use in central heating, oil complying
with the requirements of the manufac-
turer of radiator and heating element).