Controls
3
4
12
1
Master socket (this controls all 5 slave sockets)
2
Slave sockets (5x protective contact sockets)
3
Main switch ("0" = off, "I" = on), controls all 10 sockets
4
Reset button, switches the power supply on again when the overload protection has tripped
(switch off the outlet strip via the main switch first and let it cool down)
5
Control lamps
"Überspannungsschutz (Overvoltage protection)": Lights up when the overvoltage protection
is active
"Slave An (Slave on)": Lights up when the 5 slave sockets are activated
"Schutzleiter (Protective earth conductor)" (lights up when there is a protective earth conduc-
tor): If this control light is not lit, stop using the outlet strip!
6
Setting control to adjust the switching threshold from 8 - 80 W (if the power consumption at the
master socket falls below the set limit, the consumer loads connected to the 5 slave sockets (2)
are switched off; if the set limit is exceeded, the consumer loads are switched on again)
7
Fuse holder for replaceable microfuse T2.5 A (the fuse blows when the power consumption of
a consumer load connected to the master socket is too high)
8
Switch "Mater ein/aus (Master on/off)" (for switching between master/slave function and
continuous operation of all sockets)
9
RJ11 sockets with voltage surge protection (please pay attention to the arrows when connect-
ing inputs and outputs).
10 RJ45 sockets with voltage surge protection (please pay attention to the arrows when connect-
ing inputs and outputs).
11 TV sockets with voltage surge protection (please pay attention to the arrows when connecting
inputs and outputs).
12 Four sockets for continuous current (2x earthed mains sockets, 2x Euro mains sockets), which
are switched on/off via the main switch (3)
Getting started/operation
Follow the safety instructions in these operating instructions!
• If the outlet strip is placed on a desk or on the floor, use an appropriate mat to protect valuable
surfaces from scratches.
• Plug the earthed mains plug of the outlet strip into a regular earthed mains socket (wall socket).
• Connect the consumer loads to the outlet strip.
a) Operation without master/slave function
• Set the switch "Master ein/aus (Master on/off)" (8) to the position "Master ein (Master on)". The
LED "Slave An (Slave on)" lights up and stays on permanently.
• All the sockets (and the consumer loads connected to them) are switched on/off via the main
switch (3). When turned on (switch position "I"), a red control light comes on in the main switch.
b) Operation with master/slave function
• Set the switch "Master ein/aus (Master on/off)" (8) to the position "Master aus (Master off)".
• Turn the setting control with a small screwdriver gently to the left (counter-clockwise) to the
position "8 W".
• Connect the consumer load which is meant to control the slave sockets to the master socket.
Please note that the power consumption of the master device should not exceed 550 W (during
normal operation the device must have a power consumption of at least 8 W so that the master/
slave switching process can be activated).
• Switch off the consumer load connected to the master socket. The LED "Slave An (Slave on)"
should now turn off.
Should this not be the case (the master device consumes more than 8 W in standby mode or
when switched off), turn the setting control (6) for the switching threshold slowly clockwise until
the LED "Slave An (Slave on)" turns off. The loads connected to the 5 slave sockets are now
switched off.
• Switch on the consumer load connected to the master socket. The LED "Slave An (Slave on)"
should now turn on.
Depending on how the power consumption of the consumer load connected to the
master socket changes during operation, it may be necessary to readjust the setting
control (6) until the desired switching operation of the slave sockets works seamlessly.
2
1
5
6
7
9
10
11
Replacing the fuse
The fuse (7) blows when the power consumption of the consumer load connected to the master
socket is too high.
Disconnect the earthed mains plug from the mains socket (wall socket). Otherwise,
there is a risk of a life-threatening electric shock!
Unscrew the fuse holder by turning it all the way to the left (counter-clockwise).
Replace a blown fuse by a fuse of the same type and rating (5 x 20 mm microfuse, T2.5 A, 250 V).
8
Never use a fuse with higher current rating. Never bridge a defective fuse! There is a
risk of fire and a life-threatening electric shock!
Insert the new fuse into the fuse holder. Insert the fuse holder with the fuse into the outlet strip and
screw it back in its place.
Maintenance and cleaning
• The product does not require maintenance. The product contains no parts that require servic-
ing. Therefore, do not open/dismantle it. Maintenance or repair work may be performed only by
qualified personnel or a specialised repair shop.
• Switch off the outlet strip and disconnect it from the mains voltage before cleaning.
Disconnect the earthed mains plug from the mains socket (wall socket).
Also disconnect all connected loads from the outlet strip.
• To clean the product, a clean, dry and soft cloth is sufficient.
• Dust can be easily removed using a clean, soft and long-bristled brush and a vacuum cleaner.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions,
since these could damage the casing or even impair operation.
Disposal
P lease dispose of the product at the end of its life cycle according to the applicable
statutory requirements.
Technical data
Operating voltage.........................................250 V/AC, 50 Hz
Connected load ............................................Master socket: Max. 550 W (max. 2.5 A)
.........................................................................For 5 slave sockets: Max. 1700 W (max. 7.4 A) in total
.........................................................................For all 10 sockets: Max. 3680 W (max. 16 A) in total
Mains switch ................................................2-pole, with integrated red control light
Cable length ..................................................1.5 m
Voltage surge protection ............................ yes, integrated for sockets RJ11, RJ45 and TV aerial
Leakage current ...........................................9 kA
Fuse for master socket................................Microfuse 5 x 20 mm, 250 V, T2.5 A
Ambient temperature ..................................0 °C to +40 °C
Ambient humidity .........................................0% to 80% relative humidity, non-condensing
Dimensions....................................................370 x 157 x 54 mm (L x W x H)
Weight ............................................................approx. 1170 g (incl. cable)
Slight variations in dimensions and weight are dependent on the production technique.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
socket

Werbung

loading