Introduction
The KEY-2R-KPZ is an internal radio keypad
for use with Scantronic Secure Radio (SSR)
receivers. The keypad provides the same
functionality as a wired keypad, including the
ability to configure and set/unset the system.
Notes:
•
This keypad is compatible only with SSR
control units and expanders (not legacy
receivers).
•
The maximum number of radio keypads
you can use is specified in the Installer
Manual .
•
This product must be installed and
maintained only by qualified service
personnel.
Features:
•
Gives full access to configure, set or unset
the system.
•
Uses secure encrypted communications.
•
Assignable to more than one partition.
•
Local display of signal strength.
•
Easy to install.
•
Firmware updated "over-the-air" .
•
Internal proximity reader.
•
Terminals for two wired zones.
•
Navigation key for menus, with built-in
alert LEDs.
•
Backlit display and keys.
•
Configurable A, B, C, D keys.
•
Cover and back tamper detection.
Installing the KEY-2R-KPZ
Step 1: Check the location
Note:
Do not mount the KEY-2R-KPZ until
Step 5.
•
Locate the KEY-2R-KPZ out of sight of
potential intruders and within the area
protected by the intrusion system.
•
Choose a convenient location and height
for users.
•
Radio performance may reduce if the device
is mounted near metal pipes, mains wiring,
metal surfaces, electronic equipment or
radio emitters, or near the floor.
•
Make sure that the keypad is not closer than
1 metre to another proximity reader.
Scantronic Secure Radio
Installationsanweisungen
DE
Istruzioni per l'installazione
IT
Unset key / Deaktivierungstaste / Touche de désarmement / Tasto disinserimento / Uitschakeltoets
Proximity reader / Chip-Leser / Lecteur de proximité /
Lettore di prossimità / Proximitiy lezer
Programming keys / Programmiertasten / Touches de programmation /
Tasti di programmazione / Programmeertoetsen
Hold-up keys / Überfalltasten / Touches Agression /
Tasti allarme panico / Overval-toetsen
Step 2: Remove the front cover
1. Using a thumb (not a tool), flip down
the screw covers (Fig. 2) and remove the
screws.
2. Lift the cover upwards, off its hinges.
Fig. 2: Removing the cover
Step 3: Connect the batteries
Remove the insulating tab from the battery
compartment (Fig. 3).
Tamper switch
Zone terminal
block
Battery
compartment
(3x1.5V AA)
Fig. 3: PCB
Step 4: Learn the KEY-2R-KPZ
Note: If an address has been previously
allocated, you can delete it pressing D and
together while the cover is open.
1. Temporarily re-attach the front cover of
the keypad.
2. If the KEY-2R-KPZ is the control unit's first
keypad:
a) Power up the control unit.
b) Press and hold A and together at
the KEY-2R-KPZ until you see a Joining
message and the navigation LED
flashing orange.
c) After a few seconds, you should see a
message similar to the following, which
indicates that an address has been
allocated to the keypad.
P
d51
v1.00
11/06/25
™
If an address is not allocated, press and
hold A and again. If the display times
out, press the u or n key.
d) Follow the initial power-up prompts
for the control unit, as described in the
Installer Manual .
3. Alternatively, if the control unit already has
a functioning keypad:
a) At an existing keypad, use the Installer
menu to add a new KEY-2R-KPZ radio
keypad.
b) When prompted, press and hold A and
together at the KEY-2R-KPZ until
you see a Joining message and the
navigation LED flashing orange.
c) The address allocated is displayed at the
new keypad; for example:
P
d52
v1.00
11/06/25
d) The existing keypad displays the signal
strength to the receiver. The reading
must be at least 3 and ideally greater
than 5.
Note: In the Installer menu, the Test, Signal
Strengths option displays individual signal
strengths at the device and at the receiver.
Step 5: Mount the KEY-2R-KPZ
Remove the front cover. Secure the tamper
block and each corner of the backplate to the
mounting surface (Fig. 4).
Use the supplied 3mm x 19mm (No4) screw
for the tamper block
Minimum 3
off 4mm x
25mm (No8)
countersunk
screws for
backplate
Cable-entry hole (on
each side)