Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - STEINEL IS 130-2 Bedienungsanleitung

Infrarot-bewegungsmelder
Vorschau ausblenden Andere Handbücher für IS 130-2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
IS 130-2
i
9363201
1
Steinel Infrarot-Bewegungsmelder IS 130-2
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Principle
Movement triggers lights, alarms and many other devices - for your convenience and safety. The integrated
pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.).
The heat detected in this way is converted electronically into a signal that activates the load connected. Heat
radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings

Installation

L = live conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = any protective earth conductor (green/yellow)
Attention: Loop the protective-earth conductor through if necessary. A mains power switch for turning the unit
ON and OFF may of course be installed in the mains supply lead. Important: Reversing the connections may
result in damage to the unit. Please note that the circuit must be protected by a 10 A circuit breaker.
Minimum installation height: 1.70 m.
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to
Control dial set to
To adjust the detection zone in daylight, the control dial must be set to
Time setting (factory setting: 8 sec.): Light 'ON' time can be set from 8 secs. to 30 mins.
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (30 min.)
When setting the detection zone, it is recommended to select the shortest time –.
Adjust detection zone at swivel mount a
a Reach 2 – 12 m, by tilting sensor lens through 90°.
a Using adhesive shrouds, e.g. to mask out paths or neighbouring properties.
10
Important: The most reliable way of detecting motion is to install the SensorLight with the sensor aimed across
the direction in which a person would walk and by ensuring that no obstacles (such as trees and walls, for
example) obstruct the line of sensor vision. Reach is limited when walking directly towards the light.
Troubleshooting
No power / Fuse faulty, not switched on
Will not switch ON / Surroundings still too bright
Bulb faulty
Will not switch OFF / Permanent movement in the detection zone
ON/OFF / There is a light in the detection zone
when unwanted / Detecting cars on the road, for example
Reach changing / Differing ambient temperatures
down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Low Voltage Directive 06/95/EC, EMC Directive 04/108/EC and RoHS Directive
02/95/EC.
Functional warranty
This STEINEL product has been manufactured with great care, tested for proper operation and safety in accordance
with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that it is perfect
condition and proper working order. The warranty period is 36 months, starting from the date of sale to the con-
sumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts,
nor does it cover damage or defects caused by improper treatment, maintenance or the use on non-genuine parts.
Further consequential damage to other objects shall be excluded. The warranty will only be honoured if the product
is sent to the appropriate Service Centre fully assembled and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's stamp).
Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period. Please
send the product well packed to your nearest Service Centre.
2
ENGLISH
During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first
and use a voltage tester to check that the power supply is disconnected.
Installing this unit involves work on the mains voltage supply. This must therefore be carried out
in accordance with applicable national wiring regulations and electrical operating conditions.
( D - VDE 0100, A -ÖVE-ÖNORM E8001-1,
-SEV 1000)
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
a
a
1
8
a Connection with concealed wiring
5
a Connection with exposed wiring
6
a
7
= daylight operation at approx. 2000 lux.
= night-time operation at approx. 2 lux.
8
9
(Fault / Cause
Remedy)
new fuse, turn power switch ON, check lead with voltage tester.
wait until response threshold is reached or adjust setting /
change bulb / Power switch OFF
switch on / Detection zone not properly targeted
adjust detection zone. Keeps switching
change detection zone, increase distance. Switches ON
change detection zone, tilt sensor down.
at low temperatures, shorten reach by tilting sensor
3
GB
(daylight operation).
readjust.