MAINTENANCE AND STORAGE
• Place the device on the protective film after training
• Do not bend or stick the gel caps together
• Do not press the gel pads against the protective film with great force
• Do not bend the protective film
• Put the device in the case after your workout
• Keep the protective film and case clean
• Avoid exposure to high temperatures
• Use the device only for the purpose for which it was designed
• Keep the device away from fire
• Remove the batteries from the device if it is not used for a long time (approx. 1 month)
• Do not wash the appliance with water
• Do not use remover to clean the appliance
• Wash your hands before touching the gel pads
• To avoid damage and scratches, use a damp cloth to clean the unit.
• If the dirt is heavy, use a cloth soaked in water with a mild detergent to clean it.
• After cleaning, place the unit in a cool dry place.
• If the gel is dirty there will be difficulty in sticking it to the body, in which case follow the steps below:
• Put a few drops of water on your finger and spread on the gel pad to remove the dirt
• Then leave the cap to dry in a cool, dry place with the gel facing upwards
• Apply protective film when gel is dry
• Do not clean the gel for too long as this may shorten its life.
UTILISATION
The appliance must be disposed of in accordance with the law of the territory in which it is located. In the event of prolonged use, wear and tear or
damaged parts must be replaced and disposed of.
Make sure the device is switched off before disposing of it.
EXERCISE PROPOSAL
The unit will automatically switch off when the set mode is completed, press "mode" to switch modes during exercise. The user can start exercising from
the warm-up level and progress through the intensive mode to the jumping mode. We suggest not exceeding 13 cycles during an exercise session.
POSSIBLE PROBLEMS AND THEIR SOLUTIONS
If the following suggestions do not apply, ensure that the battery is correctly seated at the contact point and press down the safety flap.
The gel wears off during exercise - purchase a new pad if your device requires it.
If problems persist with the device, stop using it and contact your distributor
PROBLEM
Device does not switch on
Lack of pulse sensation
Impulse too weak
Too strong an impulse
Sudden cessation of operation
Lack of adhesion to the body
Reddened and irritable skin
LEVEL - DEVELOPMENT
Mode
Time (minutes)
M1
15
Level - intensive, combination
Mode
Time (minutes)
M2 & M3
15
M4
15
Mode
Time (minutes)
M5
15
M6
15
The battery is not in the device
Battery incorrectly inserted
The battery is discharged
Battery dead
Incorrect battery
Gel does not adhere to the skin
The gel pad is damaged
The gel is dirty
The level of intensity is low
Low power level
The gel pad is damaged
The gel is dirty
The intensity level is too high
Gel does not adhere to the skin
The battery is discharged
Gel pad is dirty
The gel pad is damaged
The gel pad is not properly adhered to the
skin
The gel pad is dry and dirty
The gel pad is damaged
Level
Session
low
1
Level
Session
high
3
medium
2
Level - stepped
Level
Session
high
3
average
2
REASON
Insert the battery into the device
Place the battery "+" upwards
Replace the battery
Use a CR2032 battery
Make sure there is no space between the
gel and the skin
Replace the gel pad
Clean the gel pad
Increase the intensity of the pulse
Replace the battery
Replace the gel pad
Clean the gel pad
Reduce the intensity level
Make sure there is no space between the
gel and the skin
Replace the battery
Clean the gel pad
Replace the gel pad
Make sure there is no space between the
gel and the skin
Clean the gel pad
Replace the gel pad