Herunterladen Inhalt Inhalt Diese Seite drucken
Salto NCoder Installationsanleitung
Vorschau ausblenden Andere Handbücher für NCoder:
INSTALLATION GUIDE
NCoder
MODEL: ELECTRONIC INFO. EC0B - EC0J - EC09 - EC0H
Copyright © 2025 Salto Systems, S.L.
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Salto NCoder

  • Seite 1 INSTALLATION GUIDE NCoder MODEL: ELECTRONIC INFO. EC0B - EC0J - EC09 - EC0H Copyright © 2025 Salto Systems, S.L.
  • Seite 2 INSTALLATION GUIDE | Nombre comercial ECxx.. series 30,5 (1-3/16") ETHERNET Cable Not included/ No incluido / Nict enthalten Non 포함되지 않음 inclus / Não incluso / Installation Instalación Montageanleitung Installation Instalação 설치 NCoder MODE PAGE 2/9 saltosystems.com...
  • Seite 3 Apenas comunicação USB. / USB To be able to work in Desktop Reader mode, the NCoder must be configured through the Space software. / Para poder funcionar en modo Desktop Reader, el NCoder debe ser configurado a través del Space. / Um im Modus “Desktop Reader“...
  • Seite 4: Electrical Characteristics

    INSTALLATION GUIDE | Nombre comercial Electrical characteristics Características eléctricas Elektrische Eigenschaften 전기적 특성 Característiques electriques Características eléctricas OPERATING CHARACTERISTICS CABLE REQUIREMENTS POWER CONSUMPTION RF CHARACTERISTICS Min. Cen. Max. Unit Min. Max. Unit Typ. Max. Unidad Ethernet UTP CAT5e RFID frecuency 13,56 Temperature °C...
  • Seite 5: Ethernet-Verbindung

    - Es posible cambiar manualmente los ajustes de dinámico a estático utilizando un navegador web. - Conectar el NCoder al ordenador utilizando un cable Ethernet (No suministrado). - Comprobar que el NCoder (v2) ha sido declarado en la "Red SALTO" y que la opción "Online" está seleccionada en las opciones del NCoder (Admin/ajustes).
  • Seite 6 연결 CONNEXION USB CONEXÃO USB - Connecter le NCoder au PC à l'aide du câble USB fourni. - Connect the NCoder to the PC using the provided USB cable. - Assurez-vous que l'option "locale" est sélectionnée dans les options - Make sure that "local" option is selected in the NCoder options NCoder (Paramètres Admin/Local).
  • Seite 7: Dipswitch Set Up

    RESET DE FÁBRICA If it is necessary to re-install the NCoder, it is possible to restart it to factory mode. If you connect power supply while pressing CLR button during 5 seconds, the NCoder will return to the same status as when it left the factory.
  • Seite 8 INSTALLATION GUIDE | Nombre comercial 관리 Maintenance Mantenimiento Instandhaltung Entretien Manutenção Dampen a lint-free cloth or cotton swap with alcohol. Gently rub the cloth back and forth across the sensor. Repeat the process once or twice as needed. Visually observe that no residual solution remains on the sensor, especially the edges. Keep the device in a safe place! Humedezca un paño sin pelusa o un algodón con alcohol.
  • Seite 9 1 sec Factory mode Cont. Addressing status Yellow Cont Waiting for initialization Blinking red 500/500 Cont. Ncoder start up Green 1 sec DR activation Yellow 1000 + Green 500 1,5 sec Silence 1000 + high pitched 50 1,5 sec SEÑAL...

Inhaltsverzeichnis