Herunterladen Diese Seite drucken
32
min: 90
min: 90
DETAIL A
SCALE 3:10
5301
5141
SEE DETAIL B
4854
4480
4106
4023
3582
2900
0
min: 10967
800
max: 11784
11998
SEE DETAIL A
10608
800
11784
SECTION A-A
32
DETAIL B
SCALE 3:10
min: 11326
800
max: 11784
SECTION A-A
SEE DETAIL C
max: 2900
SCALE 1:200
0
SEE DETAIL F
800
32
min: 90
min: 10967
800
max: 11784
EAB16
K158-1 /
SEE DETAIL D
K158-2
DETAIL F
SCALE 1:4
EAB16
min: 90
32
DETAIL D
DETAIL C
SCALE 3:10
SCALE 3:10
MULTIPLE SETUP
SCALE 1:200
800
SINGLE SETUP
NOTE: In the structural calculation according to EN 13782, the maximum height, as indicated on the drawing, has been applied. The wall dimensions are
provided as an indication to give a better understanding of the necessary preparations.
For certainty regarding the strength of the wall in relation to the forces from the canopy and the load from the compartment, we recommend having the
wall calculated by a structural engineer.
NOTITIE: In de statische berekening volgens EN 13782 is de maximale hoogte, zoals aangegeven op de tekening, gehanteerd. De afmetingen van de
wand zijn indicatief weergegeven om een beter beeld te geven van de benodigde voorbereidingen.
Voor zekerheid over de sterkte van de wand in relatie tot de krachten van de overkapping en de belasting vanuit het vak, adviseren wij om de wand door
een constructeur te laten berekenen.
HINWEIS: In der statischen Berechnung gemäß EN 13782 wurde die maximale Höhe, wie in der Zeichnung angegeben, berücksichtigt. Die Wandabmessungen
sind indikativ dargestellt, um einen besseren Überblick über die erforderlichen Vorbereitungen zu geben.
Für Gewissheit über die Festigkeit der Wand in Bezug auf die Kräfte der Überdachung und die Belastung aus dem Fach empfehlen wir, die Wand von einem
Statiker berechnen zu lassen.
NOTE: Dans le calcul statique selon la norme EN 13782, la hauteur maximale, comme indiquée sur le dessin, a été appliquée. Les dimensions du mur sont
données à titre indicatif afin de mieux comprendre les préparations nécessaires.
Pour garantir la solidité du mur face aux forces de la couverture et à la charge du compartiment, nous recommandons de faire calculer le mur par un ingénieur
en structure
LASERCUT ACCORDING: EN-ISO 9013-5-4-1
MATERIAL:
See List
MATERIAL CERTIFICATE: 3.1 (OR 2.2 WHEN S235JR)
GALVANIZING ACCORDING: EN ISO 1461
TREATMENT:
None
BEND RADIUS UNLESS DEFINED Ri=t
TOLERANCES UNLESS OTHERWISE SPECIFIED:
DIMENSION:
ANGLE:
GENERAL
MODEL NUMBER
ROUGHNESS
TCA0242
x
x
Ra x
DESCRIPTION:
CT-S-1212 on concrete wall
SCALE:
UNITS
PROJECTION: MODIFIED ON: 21-03-2025
MODIFIED BY: AVA
1:100
mm
MASS:
5487,4 kg
KROFTMAN STRUCTURES B.V. Duplication and copying without written permission of the owner is prohibited
C
K158-1 /
K158-2
STATUS: Released
REVISION:
0
APPROVED ON:
18-04-2025
APPROVED BY:
BVB
Sheet 1 of 2
Size: A2