Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing
for longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying out
calibration once a year. If necessary, contact your distributor or the
UMAREX-LASERLINER service department.
Technical Data (Subject to technical changes without notice. 25W15)
Precision (typical)*
Measurement range
(inside)**
Laser class
Laser wavelength
Memory
Automatic switch-off
Power supply
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
+/-0.2 mm/m for weakly reflective target surfaces.
** at max. 5000 lux
12
EN
± 2 mm
0,1 m - 30 m
2 / < 1 mW (EN 60825-1:2014/
A11:2021 / EN 50689:2021)
650 nm
50 memory locations
after 3 minutes
2 x 1,5V LR03 (AAA)
-10°C ... 40°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
-20°C ... 70°C, max. humidity 80% rH
40 x 121 x 28 mm
100 g (incl. batteries)