ATS1330 Power Distribution Board Installation
Sheet
EN DE
1
EN: Installation Sheet
Description
The power distribution board, model ATS1330, provides a
simple means of star connecting ATS bus devices. It is fitted
with a single protected input port and five paralleled output
ports, providing either the traditional power and comms or
power alone. It is a standard board size and provides a power
OK LED (Figure 2, item 8) for easy diagnosis.
The module has an incoming and outgoing data bus / power
connection to achieve i.e. a proper stub connection for an
Advisor Master bus reader.
Mounting location
The ATS1330 PCB (Figure 1) can be mounted in any Advisor
Master cabinet, which supports the size B board.
Connecting the ATS1330
Figure 2
(1) ATS control panel (Mains powered device)
(2) TERM — termination link
(3) GND — earthing link
(4) Building earth
(5) Remote arming station (RAS)
© 2020 Carrier
2
(6) Shield connection between mains powered and non-mains
powered device(s)
(7) 4-door DGP (mains powered device)
(8) Power OK LED
(9) DGP (mains powered device i.e. ATS1201)
TERM link fitted on first and last devices on the LAN. In a "star"
wiring configuration the TERM link is only fitted on the devices
at the ends of the two longest LAN cable runs.
Recommended LAN cable
WCAT52 — 2 pair twisted shielded data cable.
Note:
The shield of each length of data cable is only
connected at one end of a mains powered device with
earthing. The shield of the data cable cannot be connected at
the ATS1330. In case of a non-mains powered device, the
shield should be connected to the shield of the nearest mains
powered device (please refer to the shield connection between
device 5 and 7 in Figure 2).
Jumper settings
Input
Outputs
D+, D− = POWER
P+ (12 VDC)
P+
P− (GND)
P−
D+
P+
D−
P−
1 / 4
D+, D− = DATA
P+
P−
D+
D−
P/N 1077855 (ML) • REV C • ISS 14DEC20
loading

Inhaltszusammenfassung für Aritech ATS1330

  • Seite 2 Candidate List found at ECHA Web site. angeschaltet werden. Die Abschirmung des Datenkabels kann Safe use information can be found at nicht an der ATS1330 angeschaltet werden. Wird die Platine in https://firesecurityproducts.com/en/content/intrusi Geräten ohne Netzteil installiert, sollte die Abschirmung an on-intro dem nächsgelegenen Gerät mit Schutzerde angeschaltet...
  • Seite 3 Rechtliche Hinweise INVERKEHRBRINGER: Hersteller Kontaktinformationen Carrier Fire & Security Americas Corporation Inc. 13995 Pasteur Blvd www.firesecurityproducts.com oder www.aritech.com Palm Beach Gardens, FL 33418, USA Kontaktinformationen für den Kundendienst finden Sie unter BEVOLLMÄCHTIGTER EU REPRÄSENDANT: www.firesecurityproducts.com Carrier Fire & Security B.V.