Herunterladen Diese Seite drucken

Recom RACM90-K/ENC Installation Und Betriebsanleitung Seite 2

Valid for: RACM90-12SK/ENC; RACM90-15SK/ENC; RACM90-24SK/ENC;
RACM90-36SK/ENC; RACM90-48SK/ENC
Installation and Operating Instructions
AC/DC Power Supply: RACM90-K/ENC
Other applicable document:
Important Safety Information
Technical Data
At 115/230VAC, full load forced air cooling, 25°C,
with 5 minute warm-up time unless otherwise stated
nom. Output Power – continuous
Output Voltage (Factory Setting)
Output Current
Efficiency
Nominal Input Voltage Range
Operating Range
Input Current
Inrush Current (cold start)
Hold Up Time
Internal Input Fuse
Over Voltage Protection
Over Voltage Category
Over Current Protection
Operating Temperature
Operating Humidity
Operating Altitude
Storage Conditions
Dimensions / Weight
horizontal (standard)
Approvals
AC
DC
Warranty
Fig. 1: Mounting / Montage
vertical / vertikal
If module is horizontal or side mounted no derating is required. If module is mounted vertical or
upside down with natural convection cooling, the power must be derated at least 10%.
Wenn das Modul horizontal oder seitlich montiert wird, ist keine Leistungsrücknahme erforderlich. Wenn
das Modul, bei natürlicher Konfektionskühlung, vertikal oder kopfüber montiert wird, muss die Leistung um
mindestens 10% verringert werden.
vertical
Fig. 2: Block Diagram / Block Diagramm
upside-down
T4A
L
Input Filter
T4A
Eingangs-
Gleichrichter
N
filter
DC
AC
Flyback Controller
Flyback-Steuerung
Fig. 3: Derating Graph / Temperaturverhalten
100VAC
90
80
70
60
50
40
30
20
24Vout
12Vout
10
15/36/48Vout
0
-40
-20
0
20
40
45
50
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Technische Daten
Bei 115/230VAC, Volllast, Zwangsbelüftung, 25°C, nach
5 Minuten Aufwärmzeit, wenn nicht anders angegeben
nom. Ausgangsleistung - dauerhaft
Ausgangsspannung (Werkseinstellung)
Ausgangsstrom
Wirkungsgrad
Nominaler Eingangsspannungsbereich
Eingangsspannungsbereich
Eingangsstrom
Einschaltspitzenstrom (Kaltstart)
Pufferzeit
Interne Eingangssicherung
Überspannungsschutz
Überspannungskategorie
Überstromschutz
horizontal (standard)
Betriebstemperatur
AC
DC
Betriebsluftfeuchtigkeit
Betriebshöhe
Lagerbedingungen
Abmessungen / Gewicht
Zulassungen
Garantie
horizontal (standard)
AC
DC
vertical
upside-down
upside down / kopfüber
DC
AC
vertical
Active
Output Filter
Rectifier
Rectification
Ausgangs-
Aktive
filter
Gleichrichtung
upside-down
Snubber
Feedback
Regelstrecke
Snubber
DC
Rectification Controller
AC
+ Feedback Loop
Steuerung für die aktive Gleichrichtung +
Regelung der Ausgangsspannung
90
80
70
60
50
40
30
20
24/36/48Vout
12Vout
10
15Vout
0
60
80
100
-40
-20
0
90
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Revision: 0/2022
Document no.: IMG142
©RECOM Power GmbH. The information contained in
this instructions and accompanying drawings are the
intellectual property of RECOM Power GmbH.
This manual can change without prior notice.
RACM90-12SK/ENC
RACM90-15SK/ENC
90W
90W
12VDC
15VDC
7.5A
6A
87%
89%
130% - 150%, auto recovery / 130% - 150%, automatischer Neustart
OVCIII (up to 2000m) according to 61558-2-16, OVCII according to 60601-1 / OVCIII (bis 2000m) nach 61558-2-16, OVCII nach 60601-1
130% - 150%, auto recovery / 130% - 150%, automatischer Neustart
-40°C to +90°C with derating at natural convection (0.1m/s) (refer to Fig. 3) / mit Leistungsreduzierung bei natürliche Konvektion (siehe Fig. 3)
4000m (OVCII) according to 60601-1, 2000m (OVCIII) according to 61558-2-16 / 4000m (OVCII) nach 60601-1, 2000m (OVCIII) nach 61558-2-16
-40°C to +90°C, 95% RH max. (non condensing) / -40°C bis +90°C, 95% RH max. (nicht kondensierend)
CAN/CSA-C22.2 No. 60601-1:14, ANSI/AAMI ES60601-1, IEC/EN60601-1, IEC/EN62368-1, IEC/EN60335-1, IEC/EN61558-2-16, IEC/EN61558-1
Fig. 4: Mechanical Dimension / Mechanische Dimensionen
Dimension Drawing (mm) / Dimensionszeichnung (mm)
14.2
1
3
CON1
+V
-V
3.7
#
120-240VAC
1
3
4,5
6,7
FC = fixing centers
20
40
60
80
100
45
50
90
*
TechsupportAT@recom-power.com
RACM90-24SK/ENC
RACM90-36SK/ENC
90W
24VDC
3.75A
89%
50/60Hz, 100-240VAC
47-63Hz, 80-264VAC or 120-370VDC
2A @115VAC / 1.2A @230VAC
30A @115VAC / 40A @ 230VAC
12ms @115VAC / 70ms @230VAC
T4A, slow blow / T4A, Träge
95% RH max.
118.3 x 62.7 x 38.7mm / 265g typ.
3 years / 3 Jahre
118.3
7
6
Top View
5
4
Draufsicht
1
3
13.9
Front View
56.3
Ansicht von Vorne
7.5
7.5
8x Ø3.4
Bottom View
Ansicht von unten
FC 110.9
Connector Information
Function
Terminal
AC Input (CON1)
VAC in (N)
3 Pins (Pin2 removed)
VAC in (L)
with 3.96mm pitch
DC Output (CON2)
+VDC out
4 Pins
-VDC out
with 3.96mm pitch
Compatible Connector
Housing
Molex 41695 Series or equivalent
Crimp Terminal
Molex 2478 Series or equivalent
RECOM Power GmbH
Münzfeld 35, 4810 Gmunden, AUSTRIA
+43 7612 88325 700
+43 7612 88325 801
7
www.recom-power.com
RACM90-48SK/ENC
90W
90W
36VDC
48VDC
2.5A
1.87A
90%
90%
AC Input Side View
AC Eingangsseite
1
3
CON1
DC Output Side View
DC Ausgangsseite
4 5 6 7
CON2
Tolerances: xx.x= ±0.5mm
xx.xx= ±0.25mm
Anschluss
#
Funktion
Stiftleiste
AC Eingang (CON1)
1
VAC in (N)
3 Pins (Pin2 ausgelassen) mit
3
VAC in (L)
3.96mm Abstand
DC Ausgang (CON2)
4,5
+VDC out
4 Pins
6,7
-VDC out
mit 3.96mm Abstand
FC = Montagelöcher
Kompatibler Stecker
Gehäuse
Molex 41695 Serie oder equivalent
Kabelgehäuse
Molex 2478 Serie oder equivalent
loading