PRECAUTION FOR USE
• Place the diffuser on a flat and stable surface away from the edge.
• Recommended water: mineral water/tap water/at room temperature/low in limescale.
• Do not pour hot water into the container (risk of damaging sensitive components).
• Never leave water in the container when the appliance is not in use.
• Do not allow the area around the humidifier to become damp or wet.
• Do not pour drops of refresher oils into the container if there is no water. Risks of damaging the device.
• An excess of refresher oils could prevent the diffusion and damage the diffuser.
• After each use and before storage, to avoid spotting and bad smells clean the appliance:
- clean the water container and the upper part in order to remove all residues, for that, use absorbent paper impregnated with a
mild detergent (soap, washing-up liquid... Do not use aerosol sprays, solvents or abrasive products that might damage the appliance).
Then wipe it with a dry cloth.
- use a soft cloth with a little of water if necessary to clean the outside of the appliance.
- use a damp cotton bud (use only water) to clean the ceramic disk, making sure to not press too hard.
REPAIR
If the product is not working properly, check the following points:
Problems / Symptoms
No mist when the appliance
is switched on
Mist stops while the diffuser
is in operation
Insufficient mist
The light does not switch on
Should the problems persist please contact your retailer.
The manufacturer is not responsible for damages caused by improper use of the diffuser.
Causes
The appliance is not plugged in
Water level too low
Water level exceeds 150 ml
The end of part B is obstructed
Water level too low
Accumulation of water drops in the
part B
The ceramic disk is dirty
An excess of Estéban refresher oils has
been poured into the container
Accumulation of water drops in the
part B
Diffuser failure
Solutions
Make sure that the power adapter is properly connected to the
appliance and fully plugged in to the wall socket
Fill the water container
Empty out excess water
Make sure that nothing is preventing the release of the mist
Fill the water container
Switch off the diffuser, remove parts A and B then clean off the
accumulated water drops
Clean the ceramic disk as described in the « PRECAUTION
FOR USE» instructions
Empty the appliance and clean it
Switch off the diffuser, remove parts A and B then clean off the
accumulated water drops
Bring the diffuser back to the retailer within the after-sales
service support legal deadline
7