4. INSTALLATION
DE
Choosing the suitable position to install the Detector according to the gas specific gravity.
EN
IT
ES
FR
NL
FI
5. OPERATING INSTRUCTION
DK
The Gas Detector can be used independently .
(1) With DC 12V power supply, the green LED flashes once a second for about 3 minutes
continuously, that runs the inside sensor ( warm- up state) . After doing that the green LED
SE
lights, that means the Detector comes into normal working state .
(2) While detecting the gas leaking, the red LED flashes, the Buzzer sends out the v o i c e
alarm sound. The Detector will resume to the detecting state after the gas dispersed .
(3) Human voice alarm: Gas detected alarm voice:"Attention please, gas leaking."Carbon
monoxide detected alarm voice: " Attention please, carbon monoxide gas leaking, please
open the window and the door."
(4) The buzzer long beeps and the red LED ON means the inside sensor failure. Please cut
off the power, and contact the After Service Center.
(5) If the Detector runs disorderly, cut the power off and rerun again. If still in wrong,
please contact the After Service Center.
6. GAS DETECTOR TEST
To test the installed detector while using independently, you can give some gas around in
distance of 5 cm to the gas convection holes by using not ignitedlighter.
After self-testing and get into detecting state, push the test button, the CO indicator flash in
red color, meanwhile with voice alarm sound , without pushing , it will get into normal state.
The Detector will stop alarm and resume to the detecting state while the gas density educed
to lower than the alarm level.
7. NOTICE
1. The detector must be installed and connected correctly. It can not work if without the power
supply orderly.
2. Please periodically maintenance according to the directions .
3. The detector must have a test every half a year.
4. For various reasons for example changes in environmental conditions, electric or electronic
disruptions and tempering, the product may not perform as expected. The user is advised to
take all necessary precautions for his/her safety and protections of his/her property.
CARBEST | 2 in 1 Gas Detector| 802180
• The gas heavier than air
Installation height from floor:
0.3 ~1 . 0 m, Semi- diameter
to gas source: < 1.5 m
• The gas lighter than air
Installation height from
ceiling: 0.3 ~1 . 0 m
8