Herunterladen Diese Seite drucken

Verfügbare Sprachen

Assembly instruction
Connector type: 24_QN-50-3-3
EZ_141, SUCOFORM_141, MULTIFLEX_141
Suitable cables:
Parts list connector:
Assembly steps:
Picture
EZ cable
SUCOFORM
MULTIFLEX
The cable assembly of R.F. connectors can only be done by well trained assembly staff and suitable assembly equipment.
Huber+Suhner's skilled staff and specialised equipment are available to carry out complete R.F. lead-assembly on your behalf.
We mount your connectors on cables at economic prices! Please contact our representative for further details of this service.
Series QN
Process
For EZ and SUCOFORM
The tool must be set for
4 mm stripping dimension.
4
Prepare cable according to
diagram.
Form tip of inner conductor
to 90° cone.
Dimension 13.5mm applies
to SUCOFORM with jacket.
For MULTIFLEX
Dive the on length cutted
cable in flux and tin.
Cut in jacket until screen.
Remove jacket.
Remove cable dielectric and
tinned braid according to
diagram.
Form tip of inner conductor
to 90° cone.
Push prepared cable into
connector body A until stop.
Locate connector together
with cable and locator tool
74_Z-0-0-391 in soldering
fixture 74_Z-0-0-442 and
clamp.
Solder cable to connector
body A at X.
Slide shrink tube over
connector body A and shrink
with Hot-air fan.
Dimension X max. 1mm.
0000186844
Old Assembly instruction No. 27514
Inner conductor contact:
Outer conductor contact:
For MULTIFLEX cable it is recommended
to use a Shrink tube. The shrink tube is
not included in the connector.
Feature / Check
Cut cable end perpendicular
to cable axis.
Do not damage centre
contact, dielectric and braid.
The solder must flow at
behind for min. 6.5 mm. If
the cable does not fit into the
cable entry, use a flat-nose
plier to calibrate the outer
contact.
Avoid excessive heat.
Promptly swap soldered
area with alcohol to cool
joint and remove any
residual flux.
Avoid excessive heat.
Deutscher Text: siehe Rückseite
Plugged in
Soldered
Tools required
Stripping tool W 157.
See instruction sheet
DOC-0000199604 for
detailed description.
Tip trimmer tool W 164
Stanley blade
Flat-nose plier
Tip trimmer tool W 164
74_Z-0-0-391
74_Z-0-0-442
Soldering iron
Solder
Alcohol
Hot-air fan
Revision
B
Date
21.02.2012
Initiator
4191/Prm
loading

Inhaltszusammenfassung für HUBER+SUHNER QN Serie

  • Seite 2 Spalt X max. 1mm. Version Die Montage von HF-Verbindern kann nur durch geschultes Personal, das über die richtige Ausrüstung verfügt, erfolgen. Huber+Suhner verfügt über ausgebildete Fachkräfte und rationelle Einrichtungen zur Herstellung kompletter HF-Verbindungs- Datum 21.02.2012 leitungen. Wir montieren Ihre Verbinder zu wirtschaftlichen Preisen! Wenden Sie sich an unsere Vertreter.

Diese Anleitung auch für:

24 qn-50-3-3