Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
■
in our Conrad offices
■
at the Conrad collection points
■
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
7.2 (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the
product. According to the Battery Directive, end users are legally obliged to return all spent
batteries/rechargeable batteries; they must not be disposed of in the normal household
waste.
Batteries/rechargeable batteries containing hazardous substances are labelled
with this symbol to indicate that disposal in household waste is forbidden. The ab-
breviations for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury,
Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the
left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations
and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short cir-
cuit and their exposed terminals should be covered completely with insulating tape before
disposal. Even empty batteries/rechargeable batteries can contain residual energy that may
cause them to swell, burst, catch fire or explode in the event of a short circuit.
8 Technical data
Power supply
Power supply.................................. 3 V, 2x 1.5 V AA battery
Controls
Machinery control button count ...... No. 3208799: 4
Machinery control button speeds.... No. 3208799: 1
Command response time ............... <100 ms
Stop command response time........ <100ms
Wireless transmission
Frequency range ............................ 433.88 - 433.95 MHz
Transmission power ....................... <10 mW
Range............................................. max. 100 m
Modulation...................................... GFSK
Frequency control........................... PLL
Antenna impedance........................ 50 Ω
Others
Case material ................................. PA6 + 30 % GF
Ingress protection........................... IP65
Operating temperature ................... -35 to +75 °C
Storage temperature....................... -40 to +80 °C
Dimensions (W x H x D) ................. No. 3208799: 148 x 76 x 40 mm
Weight (with battery)....................... No. 3208799: 160 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*3208799 3208800_V1_0924_jh_mh_en 9007200885461003-2 I2/O1 en
4
No. 3208800: 2
No. 3208800: 1
No. 3208800: 148 x 76 x 40 mm
No. 3208800: 160 g