observe all the indications for final positioning of the apparatus. Take into account that one of the template axes must
correspond to the axis of the hood controls. Fix the bracket to the ceiling using the screws and screw anchors provided
(Fig. 5). Be careful, because the position of the bracket determines the final position of the apparatus.
3. Assemble the plate of the electrical system fixing it with 3 screws and 2 metal washers (Fig. 6).
4. Fix the telescopic structure to the bracket by means of 4 screws (provided), running the electric power cable through
the special hole in the bracket (Fig. 7). Adjust the height of the telescopic structure by means of the four retaining screws
C (Fig. 8), taking into account that the height of the hood is 48 mm and that the distance between the hood and the hob
must be at least 650 mm (Fig. 9).
5. Insert the air baffle (F) in the structure (Fig.14).
6. Through the openings E (Fig.15), fit the flange (G) to the baffle (F) locking it with a turning movement. Fix a flexible
pipe to the flange (G) for air evacuation.
7. Take the upper flue (with the slots) and fit it on the telescopic structure with the slots facing upwards; fit the flue
to the bracket with 2 screws (Fig. 16).
8. Take the lower flue and fit it in the same manner as before; slide it to the top and stop it in that position using a
screw inserted in the hole of the upper flue as a catch (Fig. 11).
9. Take the riduction (L) and assemble it onto the flange (Fig. 17).
10. Fit the hood to the telescopic structure by means of 4 screws (provided) – Fig. 18.
11. Fix the air evacuation pipe onto the reduction (L) - Fig. 18.
12. Make the electrical connection by means of the power cable.
13. Remove the screw used as catch and slide the lower flue downwards, placing it gently on the apparatus.
Installation is now complete and the grease filters can be reassembled.
INSTALLATION IN VERSION WITH AN EXTERNAL MOTOR:
Before fixing the hood the air evacuation pipe running from the hood to the intaking motor should be ready.
Use an air evacuation pipe with: – minimum indispensable length; – minimum possible bends (maximum angle of
bend: 90°); – certified material (according to the State); – an as smooth as possible inside. It is also advisable
to avoid any drastic changes in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the
outside, follow all the other instructions given on the "Warnings" sheet.
Prepare the power supply within the telescopic flue (for the electrical connection, follow all the other instructions
on the "Warnings" sheet).
Refer to the instructions for the ducting version (see point 2, 3, 4, 5, 6, 7, 8), then continue with the
instructions below.
9. Connect the hood to the external motor using the special terminal block (Fig. 19): remove wire clamp A
and lid B from the wiring junction box; fix the connecting wire of the external motor to terminal C; then replace
wire clamp A and lid B on the wiring junction box; the other end of the wire is secured to the terminal block on
the external motor.
10. Make the electrical connection by means of the power cable.
11. Remove the screw used as catch and slide the lower flue downwards, placing it gently on the apparatus.
12. Remove the charcoal filter from its case (Fig. 13).
Installation is now complete and the grease filters can be reassembled.

OPERATION

CONTROLS (Fig. 20):
Key A : Turns the lights on/off.
Key B : Reduces and increases lighting intensità.
Key C : reduces the motor speed until reaching minimum. If pressed for about 2", it stops the motor and storse the
speed.
Key D : drives the motor (calling the last speed used) and increases the speed until reaching maximum.
L Display:
- signals the running speed.
- signals the filter alarm (with motor off) by displaying the central segment for 30".
- signals Timer activation with a flashing number.
Key E : activates the TIMER (when the motor is running), so that the hood stops automatically after 5'. Also Zero-sets
hour metering when the Filter Alarm is active (motor OFF).
FILTER ALARM: Displayed for 30" when the motor is off:
After 30h of operation, the central segment lights up on the display; It indicates that the grease filters need to be
cleaned.
After 120h of operation, the central segment flashes on the display; It indicates that the grease filters need to be
cleaned and the charcoal filters replaced.
After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing
the key E during display of the filter alarm.
Grease filters: special attention must be given to the grease filters which must be periodically cleaned, whenever

Werbung