Wired Shock Sensor
Partcode: SHOCK/W
Document SAP
102018433-02
EN 50130-4: 2011 +A1: 2014
EN 50131-1: 2006 + A1: 2009
Security Grade (SG) 2
Environmental Class (EC) II
EN
1. Installation
Dimensions and weight of the sensor are shown alongside the header (H) configuration.
H1 and H2 are used to select the pulse count.
H3 enables or disables device LEDs, remove to disable LEDs.
H4 is to select high or low sensitivity range, remove for low range.
H5 is used to select LED latch on activation, remove for LED latching
Please scan the QR code for installation instructions.
Please note: Install using the screws provided with the product.
2. Installation materials
The values shown in the table indicate typical values on various materials. The materials shown (reading
from left to right) are concrete, wood and a fixed window frame.
Please note: The stated values are typical. It is advised that practical testing is performed before
installation to verify the operation. In some environments, these values may differ from stated.
3. Pulse count
Use H1 and H2 to set the pulse count needed to trigger the device into alarm. Each time the pulse count
setting is changed, the LED will flash the appropriate number of times to indicate which setting is selected.
It will verify this by indicating the pulse count setting 3 times, pausing between each verification.
4. LED & status indications
The LED will flash on initial power-up and each time the pulse count setting is changed. Use the H3 jumper
to enable or disable LEDs.
Powering up
- LED will flash on and off whilst powering up.
Vibration detected - LED will rapidly flash once.
Device triggered
- LED will rapidly flash once for pre alarm, then for one second or latch (if
selected) when in alarm.
Gross activation
- LED will flash for one second or latch (if selected).
* If latching is not selected, the LED will extinish at this point.
5. Latching feature
Remove the jumper from the H5 (or put on just one pin so that the jumper is not lost) to activate the latching
feature. If this feature is activated and the sensor is triggered, the LED on the sensor will stay on in order to
display that it has been activated. To reset, the power must be removed from the device.
6. Sensitivity
Adjust clockwise to increase sensitivity and anti-clockwise to decrease sensitivity. Use H4 to set high or low
range. If the sensor detects 'gross attack' (a vibration higher than the calibrated sensitivity), it will override
the pulse count and go directly into alarm.
7. Wiring
Examples of wiring the device to a control panel.
Please consult the control panel manual for panel terminations.
Please note: In order to comply to Grade 2 this sensor must be wired to its own input on the control panel.
Specification
Device Colour
Tamper Switches
White
50VDC at 50mA for both front
and rear tamper switches
Casing
2.5mm ABS plastics
Sensitivity
High or low ranges, adjustable
LED Colour
Blue
Operating Voltage
9 - 15VDC
Detection Method
Piezoelectric Sensor
Product Information
For electrical products sold within the European community. At the end of the electrical products life, it should not be disposed of with household
waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country. To prevent possible
damage to components, any static charge on your body needs to be eliminated before touching inside of the unit.
Warranty
This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of five years. In
the interest of continuing care and design, Pyronix Ltd reserves the right to amend specifications, without giving prior notice.
0845 6434 999 (UK) .+44(0)333 444 1280
1
29mm
2
Material
5
H1
H2
H3
H4
H5
7
Quiescent Current
~16mA at 12VDC
Shock Sensor
Alarm Current
~30mA at 12VDC
Storage Temperature
-20°C to +50°C
+ -
ALARM
Operating Temperature
-10°C to +40°C
+12v
0v
Z1
COM
International Control Panel
customer.support@pyronix.com
107.5mm
38.8g
H1
H2
H3
H4
H5
21.5mm
1. Concrete
2. Wood
1.0m
2.5m
+ -
N/C
COM
DEOL
DEOL
Shock Sensor
+ -
TAMPER
ALARM
TAMPER
Z2
Z3
+12v
0v
A
A
T
T
EOL
COM
INPUT 1
UK Control Panel
www.pyronix.com
H1
- PC
3
H2
- PC
4
H3
- LED
6
H4
- Range
5
H5
- Latch
3
H1
H2
H3
H4
H5
3. Fixed Window Frame
4
2.5m
H1
H2
H3
H4
Shock Sensor
H5
ALARM
TAMPER
6
N/O
0v
H1
+12v
H2
H3
Output
H4
H5
N/C
Shock Sensor
Shock Sensor
+ -
+ -
ALARM
TAMPER
+12v
0v
A
A
T
T
EOL
COM
INPUT 1
UK Control Panel
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
http://bit.ly/2ovH27z
Pulse Count
H1
H2
Pulse
1
2
4
6
0s
0.5s
1s
1.5s
2s
0s
0.5s
1s
1.5s
2s
0s
0.5s
1s
1.5s
2s
*
0s
0.5s
1s
1.5s
2s
*
Shock Sensor
+ -
ALARM
TAMPER
ALARM
TAMPER
+12v
0v
A
A
T
T
EOL
COM
INPUT 1
UK Control Panel