General description
TriGasAlarm warns of escaping propane / butane gas (LPG), carbonic-monoxide (CO) and gases with narcotic effect. TriGasAlarm is
suitable to warn passengers of the dangers of escaping gases before they have an effect on the passengers in a camper or Caravan.
TriGasAlarm will be fitted firmly into the vehicle
TriGasAlarm is able to
To detect gases in the surroundings already in smallest concentrations and to warn of it, long before they can have an effect
-
on people or animals.
To awaken the asleep passengers of a camper or Caravans through an alarm-sound and to alert to escaping gas.
-
TriGasAlarm, thanks to a particular sensor-technology, reacts very sensitively to all gases with narcotic effect.
For the flawless function-manner of TriGasAlarm, it is important:
-
that the environment-air preferably is not polluted
-
that TriGasAlarm is installed in height of approximately 30cm
-
that the sensor is tested for its function regularly
Instructions for Use:
With an easy pressure on the top, TriGasAlarm is switched on. After that TriGasAlarm goes through a self-test and checks the correct
function of electronics and sensor. The procedure is indicated through the short flashing up the LED's and a long sound-signal.
Immediately, TriGasAlarm goes into the calibration of the sensor, indicated through the flashing green LED. This phase lasts up to four
minutes. The calibration is completed as soon as the green LED constantly shines.
ALARM
If TriGasAlarm detects a gas concentration in the environment-air, the appliance generates a pre-alarm. At pre-alarm, an interrupted
sound is to be heard, and the red LED starts to blink. The pre-alarm lasts 40 seconds. In this time, TriGasAlarm checks the change of
the gas-concentration, in case of the same or a higher gas-concentration, after the pre-alarm you will hear the alarm. The red LED
constantly shines and a non-stop alarm-sound is to be heard. In the case that the gas-concentration after the pre-alarm vanished,
TriGasAlarm declines into the basic condition and the green LED shines.
FUNCTION-EXAMINATION
1.)
Switch on TriGasAlarm, wait until the self-test has ended and the green LED constantly shines .
2.)
Hold a gas-lighter to the lateral openings of the TriGasAlarm, you press the button of the lighter, so that gas streams out,
but no flame is generated.
3.)
After a few seconds, the pre-alarm is caused. If you keep on steaming gas into the casing, the alarm is caused after the
pre-alarm.
Technical data:
Tension
Stream-reception of Standby
Stream-reception at alarm
Volume alarm
Sensitivity
Conformity
Connection
TriGas Alarm
5V-14V
180mA
280mA
approximately 85dB
approximately 95ppm EEC
89/336EEC, 93/68EEC
black/white = + , black = -