Herunterladen Diese Seite drucken

BD Sensors KL 1 Montageanleitung Seite 2

Klemmengehäuse

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DE EN
optional für KL 2 /
Montageanleitung /
optionally for KL 2:
Mounting instructions
Klemmengehäuse / Terminal Box
KL 1, KL 2
KL 1
www.bdsensors.com
Zentrale
Headquarters
BD SENSORS GmbH
BD-Sensors-Str. 1
D - 95199 Thierstein
Deutschland / Germany
Tel.: +49 (0) 92 35 / 98 11-0
Fax: +49 (0) 92 35 / 98 11-11
Osteuropa /
Russland /
Eastern Europe
Russia
BD SENSORS s.r.o.
BD SENSORS RUS
Hradištská 817
39a, Varshavskoe shosse
CZ - 687 08 Buchlovice
RU - Moscow 117105
Tschechische Republik /
Russland /
Czech Republic
Russia
Tel.: +42 (0) 5 72 / 4 11-0 11
Tel.: +7 (0) 9 59 81 / 09 63
Fax: +42 (0) 5 72 / 4 11-4 97
Fax: +7 (0) 9 57 95 / 07 21
Diese Montageanleitung stellt einen Auszug
aus der ausführlichen Betriebsanleitung dar.
Bitte laden Sie sich diese auf unserer Home-
page herunter, falls Sie nicht mit dem Produkt
vertraut sind.
These mounting instructions are an excerpt from the complete
operating manual. It may be downloaded from our homepage, if
you are not familiar with the device.
http://www.bdsensors.de
http://www.bdsensors.com
– Technische Änderungen vorbehalten –
– Technical modifications reserved –
Englisch
WARNING! In order to avoid hazards to operators and
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
damages to the device, the following instructions have to
be performed by qualified technical personnel.
ified technical personnel.
WARNING! Adhere to the safety and operating instructions
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on o
stated in the operation manual. Effective regulations on oc-
cupational safety, accident prevention as well as national
cupational safety, accident prevention as well as national
installation standards and approved engineering tec
installation standards and approved engineering tech-
niques must in addition be complied with.
ques must in addition be complied with.
Limitation of liability
If the instructions in the operating manual are not adhered
If the instructions in the operating manual are not adhered
to or if the device is inappropriately used, modified or dam-
to or if the device is inappropriately used, modified or da
aged, liability is not assumed and warranty claims will be
aged, liability is not assumed and warranty claims will be
excluded.
Intended use
Ensure that the medium is compatible with the media-
Ensure that the medium is compatible with the media
wetted parts and that the device is suitable for the applica-
wetted parts and that the device is suitable for the applic
tion without restrictions. The technical data listed in the cur-
tion without restrictions. The technical data listed in the cu
rent data sheet is binding.
rent data sheet is binding.
Product identification
Type
Serial-
designation
Ordering code
Ordering code
number
Wiring diagrams
KL 1
KL 2
supply
supply +
KL 2
V
S
with
supply
supply -
®
HART
®
HART
RS 232 C
PC
Interface
For the electrical connection a shielded and twisted
For the electrical connection a shielded and twisted
multicore cable is recommended
multicore cable is recommended.
The ground wires of all components have to be connected
The ground wires of all components have to be connected
when installing!
The supply V
has to be chosen according to needs of the
has to be chosen according to needs of the
S
used transmitter.
Mounting
WARNING! Install the device only in currentless state!
KL 1
ground
4 mm²
mounting hole
housing depth
housing depth
height of
housing: 58 mm.
housing: 58 mm.
cable gland
pressure
M16x1.5
balance item
(cable Ø5 ... 10 mm)
Pin configuration
Electrical connection
Electrical connection
Designation
Terminal block
(cable colours of BD SENSORS
(cable colours of BD SENSORS
(from left)
GND
SENSOR
ground clamp (gn/ye, green
VS-
SENSOR
VS+
SENSOR
GND
SUPPLY
VS+
SUPPLY
VS-
SUPPLY
IN+
TRANSMITTER
IN-
TRANSMITTER
GND
TRANSMITTER
ground clamp (gn/ye, green
IN+
SUPPLY
IN-
SUPPLY
GND
SUPPLY
HART
HART (optional)
For more information, please read the detailed operating manual
For more information, please read the detailed operating manual!
KL 2
hole
HA_
ON
HART
58 mm.
58 mm.
cable gland
pressure
M16x1.5
balance item
(cable Ø5 ... 10 mm)
to connected with
transmitters)
transmitters)
KL 1
gn/ye, green / yellow)
cable shield of transmitter
supply
- (bn, brown)
negative connecting cable of transmitter
supply +
supply + (wh, white)
positive connecting cable of transmitter
ground clamp
ground clamp
cable shield of supply line
supply +
supply +
positive signal line for pressure signal
supply -
supply
negative signal line for pressure signal
KL 2
supply + (wh, white)
supply + (
positive connecting cable of transmitter
supply
- (bn, brown)
negative connecting cable of transmitter
gn/ye, green / yellow)
cable shield of transmitter
supply +
supply +
positive signal line for pressure signal
supply
supply -
negative signal line for pressure signal
cable shield of supply line and solid wire (with
ground clamp
ground clamp
overvoltage protection)
-
HART
-modem
housing depth
55 mm.
mounting hole ∅ 4,2
height of
housing: 55 mm.
MA_KL_160118

Werbung

loading

Diese Anleitung auch für:

Kl 2