Recom RACM600-L/OF Installation Und Betriebsanleitung Seite 2

Werbung

Valid for: RACM600-24SL/OF
Installation and Operating Instructions
AC/DC Power Supply: RACM600-L/OF
Other applicable document:
Important Safety Information
Technical Data
At 230VAC, full load forced air cooling, 25°C, with 5 minute
warm-up time unless otherwise stated
Max Output Power
Output Voltage (Factory Setting)
Output Voltage Adjustability
Max. Output Current
Efficiency
Nominal Input Range
Operating Range
Input Current
Inrush Current (cold start)
Hold Up Time
5VSB Stand By Output Voltage
5VSB Stand By Output Current
Internal Input Fuse
Over Voltage Category
Over Voltage Protection Main Output
Over Current Protection Main Output
Short Circuit Protection Main Output
Over Temperature Protection Main Output
Over Voltage Protection 5VSB
Over Current Protection 5VSB
Short Circuit Protection 5VSB
Over Temperature Protection 5VSB
Operating Temperature Range
Storage Conditions
Operating Humidity
Operating Altitude
Dimensions / Weight
Approvals
Warranty
Fig. 1: Derating Graph / Temperaturver
200-240VAC (±10)
600
500
450
400
300
200
2.5m/s
1.5m/s
100
natural convection 0.1m/s
0
-20
-10
0
10
20
30
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Fig. 2: Output Voltage Adjustability / Regulierbarkeit der Ausgangsspannung
25
20.8
0
19.2
24
Output Voltage [VDC]
Ausgangsspannung [VDC]
Make sure that the maximum rated output power will not be exceeded when trimming up as well.
Achten sie darauf dass auch während des Hochtrimmens die jeweils maximal zulässige
Ausgangsleistung nicht überschritten wird.
©RECOM Power GmbH. The information contained in
this instructions and accompanying drawings are the
Technische Daten
Bei 230VAC, Volllast, Zwangsbelüftung, 25°C, nach 5 Minuten
Aufwärmzeit, wenn nicht anders angegeben
Max. Ausgangsleistung
Ausgangsspannung (Werkseinstellung)
Einstellbereich der Ausgangsspannung
Max. Ausgangsstrom
Wirkungsgrad
Nominaler Eingangsbereich
Betriebsbereich
Eingangsstrom
Einschaltspitzenstrom (Kaltstart)
Pufferzeit
5VSB (Ständige Bereitschaft) Hilfsausgang Spannung
5VSB (Ständige Bereitschaft) Hilfsausgangsstrom
Interne Eingangssicherung
Überspannungskategorie
Überspannungsschutz Hauptausgang
Überstromschutz Hauptausgang
Kurzschlussschutz Hauptausgang
Übertemperaturschutz Hautausgang
Überspannungsschutz 5VSB
Überstromschutz 5VSB
Kurzschlussschutz 5VSB
Übertemperaturschutz 5VSB
Betriebstemperatur
Lagerbedingungen
Betriebsfeuchtigkeit
Betriebshöhe
Abmessungen / Gewicht
Zulassungen
Garantie
600
500
400
370
320
300
200
100
0
40
50
60
70
80
-20
Output power derating for Line-input of less than 90VAC (de-rate linearly from 100% at 90VAC to 80% at 80VAC)
Beachten sie eine Leistungsrücknahme für Eingangsspannungen unterhalb 90VAC (Reduzierung linear von 100% bei 90VAC auf 80% bei 80VAC)
Fig. 3. Peak Load Capability / Spitzenlastfähigkeit
Calculation Guideline for recurrent dynamic load cycles: Berechnungsleitfaden für wiederkehrende dynamische Lastwechsel:
Peak Load calculation for
recurrent dynamic loading
Parameters
P
P
P
t
t
nom. P
= 600W
OUT
k= heat dissipation factor
Berechnung der Spitzenlast für
Wiederkehrende dynamische Belastung
Parameter
28.8
P
P
P
t
1
t
2
k= Wärmeableitfaktor
Revision: 2/2023
Document no.: IMG140
intellectual property of RECOM Power GmbH.
This manual can change without prior notice.
2x T10A, (L & N, dual fusing / Doppelsicherung) DC input compliant / DC-Eingangsspannungskonform
108-140% of rated output current, auto recovery / des Nennausgangsstromes & automatischer Neustart
1-1.3A of rated output current auto recovery / des Nennausgangsstromes, Automatischer Neustart
-20°C to +70°C with derating (refer to Fig. 1) / mit Leistungsreduzierung (siehe Fig. 1)
-40°C to +85°C, 95% RH max. (non condensing) / (nicht kondensierend)
3000m max. (according to 60601-1; 5000m max according to 62368-1 / 3000m max. gemäß 60601-1; 5000m max. gemäß 62368-1
High altitude operation may impact the performance and lifetime. Please reduce output power, when operating >2000m above sea level.
Betriebshöhen über 2000m beeinflussen die Lebensdauer und erfordern eine Reduzierung der Ausgangsleistung.
IEC/EN/UL 62368-1, ANSI/AAMI ES 60601-1, CSA C22.2 No. 60601-1:14, IEC/EN 60601-1
115VAC (±10)
2.5m/s
1.5m/s
natural convection 0.1m/s
-10
0
10
20
30
40
50
60
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Peak Load calculation for
still air convection
Units
RACM600-24SL/OF
= rated output power
[W]
refer to derating graph Fig1
nom
= peak output power
[W]
P
= recovery output power
[W]
refer to calculation
r
= peak time set
[s]
1
= recovery time
[s]
2
[ ]
Units
= Nominale Leistung
[W]
siehe Temperaturverhalten Fig1
nom
= Spitzenlast
[W]
P
= Leistung der Entlastungsphase
[W]
r
= Zeitspanne der Überlast
[s]
= Entlastungszeit
[s]
[ ]
*
techsupportemea@recom-power.com
RACM600-24SL/OF
600W
24VDC
19.2-28.8VDC (200mV steps/Schritte)
25A
93%
50/60Hz, 100-240VAC
47-63Hz, 80-275VAC / 120-300VDC
100-240V, 50/60Hz: 6.8-2.7A
20A
20ms
5VDC
500mA max.
OVC II
30-35VDC, latch off / speichernd abschaltend
auto recovery, hiccup mode / Automatischer Neustart
auto recovery / Automatischer Neustart
5.5-6VDC, latch off / speichernd abschaltend
auto recovery / Automatischer Neustart
auto recovery / Automatischer Neustart
95% RH max. (non-condensing / nicht kondensierend)
196.8 x 101.6 x 40.6mm / 1000g typ.
3 years / 3 Jahre
400
350
300
250
200
150
100
2.5m/s
1.5m/s
50
natural convection 0.1m/s
0
70
80
-20
-10
0
Pout [W]
P
p
≤600
≤5s
P
nom
min. 8 x t
1
P
2
r
Spitzenlast für
0
Ruhende Luftkonvektion
RACM600-24SL/OF
Calculation / Berechnung:
≤600
siehe Berechnung
P
=
r
≤5s
min. 8 x t
1
2
RECOM Power GmbH
Münzfeld 35, 4810 Gmunden, AUSTRIA
+43 7612 88325 700
+43 7612 88325 801
7
www.recom-power.com
100VAC (±10)
10
20
30
40
50
60
70
80
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Time [s]
t
t
1
2
P
x (t
+ t
) - (P
x t
)
nom
1
2
P
1
t
x k
2