Quick start guide
Power Inverter (1000
Watt)
For more information see the extended manual online:
ned.is/pim100012egy
Intended use
This product is a power inverter to convert 12/24 V DC to 230 V AC.
Check the specifications of your model.
4
The modified sine wave power inverters are less suitable for
4
devices with a motor. Use a pure sine wave power inverter
(PIPxxxxxGY).
Only use this product in combination with class II devices.
Do not use this product with:
Devices that exceed the rated power of the inverter.
Capacitive and perceptual load devices such as air conditioning,
high power drills, fridges, microwave ovens, or blenders.
Devices that have strict power supply requirements, such as
precision measuring equipment.
The product is intended for indoor use only.
Any modification of the product may have consequences for safety,
warranty and proper functioning.
The product is not intended for professional use.
Main parts (image A)
1
Power inverter
2
Power cables
Main parts (image B)
1
Cable terminal +
Cable terminal -
2
Power socket
3
4
Power indicator LED
Safety instructions
-
WARNING
Ensure you have fully read and understood the instructions in
this document before you install or use the product. Keep the
packaging and this document for future reference.
Only use the product as described in this document.
Do not install the product next to flammable materials.
Do not place the product in areas with high temperature or
direct sunlight.
Do not cover or obstruct the ventilation openings on the
product.
Do not immerse the product in water or other liquids.
Do not expose the product to water, rain, moisture, or high
humidity.
Do not operate the product close to combustible gas or open
fire.
Do not operate appliances that may feed power back into the
power inverter.
Do not open the product, there are no user serviceable parts
inside.
Disconnect the product from the power source before cleaning.
Disconnect the product from the power source before service
and when replacing parts.
Do not use the product if a part is damaged or defective. Replace
a damaged or defective product immediately.
Do not let children play with the packaging material. Always
keep the packaging material out of the reach of children.
Always keep the power cable and the product away from usual
walkways.
Do not drop the product and avoid bumping.
PIM100012EGY PIM100012FGY
PIM100024EGY PIM100024FGY
5
Power switch
USB port
6
Fault indicator LED
7
Do not use aggressive chemical cleaning agents when cleaning
the product.
This product may only be serviced by a qualified technician for
maintenance to reduce the risk of electric shock.
Mounting the power inverter
-
Keep at least 50cm of space to the wall from the fans on the rear
of the power inverter.
1. Hold the power inverter in the desired position.
2. Mark four holes with a pencil using the power inverter as a
template.
3. Drill the holes using a power drill and a drill bit.
4. Mount the power inverter on the desired position using screws.
Connecting the power inverter (Image C)
-
Wear protective gloves when installing the power cables.
-
Use tools with insulated handles when installing the power
cables.
1. Connect the power cables A
rear of the power inverter B
2. Connect the other end of the power cables to a 12/24 V battery
system.
-
Make sure the polarity matches the polarity of the battery.
Powering a socket device
-
Make sure the target device is switched off before connecting it.
1. Plug the power plug from a target device into the power socket
B
.
3
2. Set the power switch B
The power indicator LED B
4
-
Do not load the power inverter more than 80% during long use
(>1 hour).
Powering a USB device
1. Plug a USB cable into the USB port B
2. Plug the other end of the USB cable into your target device.
3. Set the power switch B
The power indicator LED B
4
Troubleshooting
If the target device is not receiving power, look at the indicator LEDs
and listen for alarms. The table below shows what the combinations
of lights and sounds mean.
Power
Fault
Alarm
LED
LED
Off
Off
No
On
Off
Yes
On
Off
Yes
4
2
to the cable terminals on the
B
1
2
.
5
to ON.
4
switches on.
6
of the power inverter.
5
to ON.
4
switches on.
Possible
Possible solution
cause
The power
Switch on the power
inverter is
inverter.
switched
off
The
Recharge the battery.
battery is
empty.
Replace the battery.
Low
Recharge the battery.
voltage
alarm
Replace the battery.
Low
Recharge the battery.
voltage
shutdown
Replace the battery.