KZ700 Mounting Base Installation Sheet
EN DE ES FR
IT
NL PL PT RU SV
1
EN: Installation Sheet
Description
This document includes installation information for the KZ700
Mounting Base for conventional detectors. For pipe installation
the S700 pipe installation mount (not supplied) is required.
Installation
Caution:
For general guidelines on system planning, design,
installation, commissioning, use, and maintenance, refer to the
EN 54-14 standard and local regulations.
Connection
Connect the line as follows:
Terminal 1 – Line in / out (positive)
Terminal 3 – Line out (negative)
Terminal 4 – Line in (negative)
Connect remote indicators as follows:
Terminal 1 – Remote indicator (positive)
Terminal 2 – Remote indicator (negative)
See Figure 1.
Cabling requirements
WARNING:
To ensure correct operation of your system, you
must follow the recommended cabling practices described
below.
© 2013 UTC Fire & Security. All rights reserved.
The cable used should:
Have a cross-sectional area of at least 1.5 mm²
Have maximum resistance of 13.3 Ω / km per core
Maintenance
Basic maintenance consists of a yearly inspection.
Specifications
Number of terminals
Earth contact
Remote indicator connection
IP rating
Operating temperature
Storage temperature
Relative humidity
Dimensions (Ø × H)
Regulatory information
Certification
Manufacturer
Gulf Security Technology Co.,Ltd
80, Changjiang East Road, QETDZ,
Qinhuangdao, Hebei Province, China 066004
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
1 / 8
4
No
Yes
IP30
−10 to +50ºC
−10 to +70ºC
10 to 95% noncondensing
103 x 23 mm
P/N 55370166 • REV 05 • ISS 31OCT13

Werbung

loading

Inhaltszusammenfassung für Kilsen KZ700

  • Seite 1 Have maximum resistance of 13.3 Ω / km per core • Description Maintenance This document includes installation information for the KZ700 Mounting Base for conventional detectors. For pipe installation Basic maintenance consists of a yearly inspection. the S700 pipe installation mount (not supplied) is required.
  • Seite 2 Sie in der Norm EN 54-14 und in den örtlich geltenden Descripción Vorschriften. Este documento incluye información para la instalación de la base convencional KZ700. Para instalación con tubo visto es Verbindung necesario el uso del suplemento S700 (no incluido). Verbinden Sie die Linie wie folgt: •...
  • Seite 3 à la Questo documento fornisce le informazioni di installazione directive EN 54-14. della base KZ700 per il fissaggio dei rivelatori. Per l’installazione con tubo esterno è necessario utilizzare il distanziale S700 (non fornito con la base da richiedere a parte)
  • Seite 4 EU-geautoriseerde vertegenwoordiger autorizzato per l'UE: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands Omschrijving Dit document bevat installatie informatie voor de KZ700 Contact informatie conventionele detector montagevoet. Voor buis installatie wordt de S700 buis installatie voet (niet meegeleverd) Bezoek onze website voor contact informatie: aanbevolen.
  • Seite 5 Descrição Połączenia Este documentos inclui informação de instalação sobre a base Połączeń należy dokonać zgodnie z poniższym opisem: para detector KZ700. Para instalação em tubo é necesario as instruções S700 (não fornecidas). Zacisk 1 – wejście/ wyjście linii (plus) •...
  • Seite 6 • Beskrivning Контакт 3 – Выход шлейфа - • Контакт 4 – Вход шлейфа - • Detta dokument beskriver installation av KZ700 konventionell sockel. Подключение выносного индикатора (ВУОС): Контакт 1 – Выносной индикатор (ВУОС) + • Installation Контакт 2 – Выносной индикатор (ВУОС) - •...
  • Seite 7 Kabel krav Varning: Koppla bort centralen från nätspäningen och batterierna innan du tar bort, ersätter eller lägger till en modul. Kabel krav: • Bör ha en area på minst 1.5 mm² Max resistans är 13.3 Ω per km • Underhåll Grundläggande underhåll har reducerats till en årlig inspektion.
  • Seite 8 8 / 8 P/N 55370166 • REV 05 • ISS 31OCT13...