Red light
Battery may be faulty
flashing
• Recharge the battery and
monitor battery performance
for seven days.
• If the light flashes within seven
days, the battery should be
checked by a battery specialist
and replaced if necessary.
Battery selection and management
This section refers exclusively to rechargeable, wet-cell lead-acid batteries, for example car,
tractor, truck, marine or specialist deep-cycle batteries.
The battery you select will depend on whether your installation is a battery-only or a solar
installation. For both types of installation, the position of the energiser selector switch will
determine the size of battery and solar panel required. Refer to "Operation" for an explana-
tion of the function of the selector switch.
Battery selection for a battery-only energiser
As a guide, the amp hour (Ah) rating of the 12 V lead-acid battery required for each model is
shown below. The table is based on an operating period of 14 days with full power and fast
pulse.
Energiser Model
P250
P350
Battery Capacity
36 Ah
66 Ah
- 40 -
properly and that the wiring is intact.
• Battery may be over-charged or faulty:
• Disconnect the solar panel for 24 hours.
• Reconnect the solar panel and monitor
for seven days.
• If the light flashes within seven days,
there may be something wrong with the
system.
• Take the entire system to an authorised
service agent for assessment.
Battery may be faulty
• Recharge the battery and monitor bat-
tery performance for seven days.
• If the light flashes within seven days,
the battery should be checked by a
battery specialist and replaced
if necessary.
Operating time (days)
14
14