Herunterladen Inhalt Inhalt Diese Seite drucken
www.videolarm.com
P D W 7 C S - 9
Explosion-Proof: Purge/ Pressurization Unit
PDW7CN-9
IP Network Ready 7" Explosion-Proof PurgeDome™ Outdoor
PTZ Camera Systems for Hazardous environments UL
approved for Class 1, Division II applications. Includes
Purging System and Lines. With 23x zoom Day/Night
camera, MPEG-4 & MJPEG video compression,
Full D1. Clear dome, with 24VAC input, heater/ blower
PDW7CS-9
Analog 7" Explosion Proof PurgeDome™ Outdoor PTZ Camera
Systems for Hazardous environments UL approved for
Class 1, Division II applications. Includes Purging System
and Lines. With 23x zoom Day/Night camera, MPEG-4 &
MJPEG video compression, Full D1. Clear dome, with
24VAC input, heater/ blower
B e fo re a t te m p t i n g to co n n e c t o r o p e ra te t h i s p ro d u c t, p l e a s e re a d t h e s e
i n s t r u c t i o n s co m p l e te l y. To b e u s e d w i t h t h e 8 1 - I N 5 4 0 9 I n s t r u c t i o n M a n u a l .
All manuals and user guides at all-guides.com
81-IN5410
01-30-2009
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Moog Videolarm PDW7CS-9

  • Seite 1 All manuals and user guides at all-guides.com www.videolarm.com P D W 7 C S - 9 Explosion-Proof: Purge/ Pressurization Unit PDW7CN-9 IP Network Ready 7” Explosion-Proof PurgeDome™ Outdoor PTZ Camera Systems for Hazardous environments UL approved for Class 1, Division II applications. Includes Purging System and Lines.
  • Seite 2: Important Safeguards

    All manuals and user guides at all-guides.com IMPORTANT SAFEGUARDS SAFETY PRECAUTIONS Read these instructions. Keep these instructions. CAUTION Heed all warnings RISK OF ELECTRIC SHOCK DO NOT OPEN Follow all instructions. Do not use this apparatus near water. CAUTION: TO REDUCE THE RISK OF Clean only with damp cloth.
  • Seite 3: Limited Warranty

    All manuals and user guides at all-guides.com LIMITEDWARRANTY FOR VIDEOLARM INC. PRODUCTS VIDEOLARMINC. warrantsthis Productto be free from defectsin materialor workmanship,as follows: PRODUCTCATEGORY PARTS LABOR All Enclosures and Electronics Five (5) Years Five (5) Years Pan/Tilts Three (3) Years **6 months if used in autoscan Three (3) Years **6 months if used in autoscan /tour operation /tour operation...
  • Seite 4 All manuals and user guides at all-guides.com Content of Box Content of Box PROTECTED CAMERA ENCLOSURE SUPPLIED 1/4 “ & 3/8 ” POLY TUBING PAN / TILT DOME PURGE / PRESSURIZATION UNIT HARDWARE...
  • Seite 5 All manuals and user guides at all-guides.com     Unit is shipped with 100’ (max) flex tubing (3/8” & 1/4”) to connect enclosure to purge pressurized unit. 2 fitting are provided as shown in the diagrams. ENCLOSURE SUPPLY OUTLET ...
  • Seite 6: Pepperl Fuchs

    All manuals and user guides at all-guides.com NOTES • To ensure adequate protective gas flow to the protected enclosure, all piping and tubing must be fully reamed. English • Precaution must be taken to prevent crimping and other damage to protective gas piping and tubing.
  • Seite 7 All manuals and user guides at all-guides.com TUBING CONNECTION DIAGRAMS ENCLOSURE SUPPLY OUTLET ENCLOSURE REFERENCE INLET PEPPERL FUCHS PURGE/PRESSURIZATION UNIT SYSTEM SUPPLY INLET TUBING CONNECTION DIAGRAMS DOME PRESURE GAUGE [ENCLOSURE] ATMOSPHERIC SDOEN OF WOSTOE PRESURE SAFE HIGH REFERENCE SWITCH ENCLOSURE PRESSURE REFERENCE PROTECTED CAMERA...
  • Seite 8: Set-Up Procedure

    All manuals and user guides at all-guides.com CONNECTION SIZES, LENGTHS & BENDS CAMERA PEPPERL FUCHS PROTECTED REFERENCE GAS SUPPLY CAMERA (System Supply) ENCLOSURE CAMERA PURGE/PRESSURIZATION UNIT SUPPLY System Supply Camera Supply Camera Reference 3/8” OD SS Tubing SUPPLIED SUPPLIED Fully Reamed 3/8”...
  • Seite 9: Wall Mount

    All manuals and user guides at all-guides.com WALL MOUNT: The power box may be pole mounted with the Attach unit securely to the wall mount using (4) 3/8” pole support clips. (Stainless steel straps not or 8mm hardware (not supplied). provided).
  • Seite 10 All manuals and user guides at all-guides.com OUTPUT: (24VAC 84VA) HEATERS CAMERA 52 WATTS 32 WATTS Connect Housing Power Optional 24Vac 24Vac Power Output Main To Housing Switch Internal resettable fuses are supplied for the main 24VAC output lines. Do not connect heaters to camera output.
  • Seite 11 All manuals and user guides at all-guides.com To install the dome align the tabs and twist Hand tighten the screws on the dome. counter clockwise to secure. Recommended torque 12 inches/lb (1.35Nm). Part Number Description Replacement Parts List RP65PT851200 PAN TILT PR25DCP71000 TRIM RING ASSEMBLY WITH CLEAR DOME...
  • Seite 12 All manuals and user guides at all-guides.com www.videolarm.com S - V I E W PA N / T I LT Analog & IP Installation and Operation Supplement: B e fo re a t te m p t i n g to co n n e c t o r o p e ra te t h i s p ro d u c t, 81-IN5409 p l e a s e re a d t h e s e i n s t r u c t i o n s co m p l e te l y.
  • Seite 13: Electrical Specifications

    All manuals and user guides at all-guides.com Electrical Specifications Content of Box S-VIEW PAN/ TILT Class 2 Power Supply Only MODELS: 24 VAC S-view: Analog 13 WATTS S-view: IP 28 WATTS MODELS: 12VDC English S-view: Analog 13 WATTS S-view: IP 20 WATTS Fuente De Alimentación De la Clase 2 Solamente.
  • Seite 14 All manuals and user guides at all-guides.com CAPTIVE SCREW Remove Pan/Tilt from shipping carton. To secure in place, tighten captive screw. Install in base bracket in housing. • Para asegurar en lugar, apriete el tornillo prisionero. • Quite Pan/Tilt del cartón del envío. Instale en soporte bajo en la cubierta.
  • Seite 15 All manuals and user guides at all-guides.com (Analog) PROTOCOLS VL422 PELCO P 4800/9600 PELCO D 4800/9600 To set the address at “0” side the all switches off The S-View Pan/Tilt support the above protocols. as shown. See table in back for address 0-255 This is done automatically no settings are required.
  • Seite 16 All manuals and user guides at all-guides.com (IP) (IP) Select Pan/Tilt PreSets functions (also used to scroll camera menu) Lens Functions Use to save or remove PreSets IP INSTRUCTIONS: The factory default IP Control interface for IP PTZ control. address is : 192.168.0.200. •...
  • Seite 17 All manuals and user guides at all-guides.com DISPLAY / MENU DISPLAY / COMPASS Use this submenu to activate compass heading. Press zoom in to turn on, zoom out to turn off, Pan Left to exit. Use Up & Down control on the controller to navigate through the menu.
  • Seite 18 All manuals and user guides at all-guides.com DISPLAY / ADDRESS DISPLAY / TEMP. When activated this will display camera’s Will display temperature data from Pan/Tilt on address on the monitor. monitor. • Cuando está activado esto exhibirá la dirección de la •...
  • Seite 19 All manuals and user guides at all-guides.com CAMERA / STABILIZATION ALARM / MENU Camera sub menu includes, image stabilization, day/night mode, shutter, Use sub menu to activate alarm. When backlight, AGC and digital zoom. Image enabled camera will go to preset “1” when stabilization is not a feature of all cameras.
  • Seite 20: Systeminfo

    All manuals and user guides at all-guides.com ZONE / LLIMIT ZONE / TITLE Llimit will “turn off” menu and allow you to Shows on menu screen title characters position camera for left limit of zone. selected. • Voluntad de Llimit "dar vuelta apagado" al menú y permitir que •...
  • Seite 21 All manuals and user guides at all-guides.com PRESETS PRESETS Allows user to set dwell time for each existing stored Allow user to set dwell time for each stored preset. If preset. The above screen show (6) stored presets, with presets have not been saved the dwell time for that dwell times of, 9,5,12,5,5,5 seconds.
  • Seite 22: Other Features

    All manuals and user guides at all-guides.com 1, 2, 3... To set a manually controlled pattern by Using the joystick move Pan/Tilt to desired joystick set Preset 80 (80,#, positions where you can record up to 128 seconds of movement. •...
  • Seite 23 All manuals and user guides at all-guides.com Table 1: Pan/Tilt Address Dip Switch Settings ADDRESS ADDRESS ADDRESS...
  • Seite 24 All manuals and user guides at all-guides.com ADDRESS ADDRESS ADDRESS ADDRESS...
  • Seite 25 All manuals and user guides at all-guides.com ADDRESS ADDRESS ADDRESS ADDRESS...
  • Seite 26: Replacement Parts List

    All manuals and user guides at all-guides.com Replacement Parts List Part No. Description RP6039mm1.8 Motor (2) RPVL2314 Hub Bracket RP40CASL385 Slip Ring Assembly (2) RPVL2315 20T 80 Pitch Pulley (2) RP605007 Bearing RPVL2316 90T Pan Pulley RPVL2318 60T Tilt Pulley RPVL2320 Tilt Bearing Hub RP605011...
  • Seite 27: Product Information

    All manuals and user guides at all-guides.com Product Registration/Warranty Thank you for choosing Videolarm. We value your patronage and are solely committed to providing you with only the highest quality products available with unmatched customer service levels that are second-to-none in the security industry. Should a problem arise, rest assure that Videolarm stands behind its products by offering some of the most impressive warranty plans available: 3 Years on all Housings, Poles, Power Supplies, and Accessories and 5 Years on...

Diese Anleitung auch für:

Videolarm pdw7cn-9

Inhaltsverzeichnis