NV175 Instruction Manual
ENGLISH
General Safety Instructions:
READ SAFETY INSTRUCTIONS
Servicing:
These products are not customer serviceable. TDK-Lambda UK LTD. and their authorised agents only are permitted
to carry out repairs.
Critical Components:
These products are not authorised for use as critical components in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the Managing Director of TDK-
Lambda EMEA.
Product Usage:
These products are designed for use within a host equipment which restricts access to authorised competent
personnel.
This product is a component power supply and is only to be installed by qualified persons within other equipment and
must not be operated as a stand alone product.
This product is for sale to business to business customers and can be obtained via distribution channels.
It is not intended for sale to end users.
This product is a component power supply and does not fall within the scope of the EMC directive. Compliance with
the EMC directive must be considered in the final installation. Please contact your local TDK-Lambda office
Environmental:
These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be used.
Environment:
This power supply is a switch mode power supply for use in applications within a Pollution Degree 2, overvoltage
category II environment. Material Group IIIb PCB's are used within it.
Output Loading:
The output power taken from the power supply must not exceed the rating stated on the power supply label, except
as stated in the product limitations in this instruction manual.
Input Parameters:
This product must be operated within the input parameters stated in the product limitations in this instruction manual.
End of Life Disposal:
The unit contains components that require special disposal. Make sure that the unit is properly disposed of at the
end of its service life and in accordance with local regulations.
RISK OF ELECTRIC SHOCK
High Voltage Warning:
Dangerous voltages are present within the power supply. The professional installer must protect service personnel
from inadvertent contact with these dangerous voltages in the end equipment.
This product must be reliably earthed and professionally installed in accordance with the prevailing local electrical
wiring regulations and safety standards.
The (+) or (-) output(s) can be earthed or left floating.
The unit cover(s)/chassis must not be made user accessible.
Page 1 of 27
17159 issue 32, October 2021

Werbung

loading

Inhaltszusammenfassung für TDK-Lambda NV175

  • Seite 1 General Safety Instructions: READ SAFETY INSTRUCTIONS Servicing: These products are not customer serviceable. TDK-Lambda UK LTD. and their authorised agents only are permitted to carry out repairs. Critical Components: These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of TDK- Lambda EMEA.
  • Seite 2 An internal fuse protects the unit and must not be replaced by the user. In case of internal defect, the unit must be returned to TDK-Lambda UK LTD or one of their authorised agents. WARNING: These products are Class 1 and must therefore be reliably earthed and professionally installed in accordance with the prevailing electrical wiring regulations and the safety standards covered herein.
  • Seite 3 Allgemeine Sicherheitsvorschriften: LESEN SIE DIE SICHERHEITSVORSCHRIFTEN Wartung: Diese Produkte können nicht durch den Kunden gewartet werden. Nur TDK-Lambda UK LTD. und deren zugelassene Vertriebshändler sind zur Durchführung von Reparaturen berechtigt. Kritische Komponenten: Diese Produkte sind nicht für die Verwendung als kritische Komponenten in nuklearen Kontrollsystemen, Lebenserhaltungssystemen oder Geräten in gefährlichen Umgebungen geeignet, sofern dies nicht ausdrücklich und...
  • Seite 4 Verwenden Sie keine Befestigungsschrauben, die mehr als 4.5mm in das Gerät eindringen. Eine interne Sicherung schützt das Gerät und darf durch den Benutzer nicht ausgetauscht werden. Im Fall von internen Defekten muss das Gerät an TDK-Lambda UK LTD oder einen der autorisierten Vertriebshändler zurückgeschickt werden.
  • Seite 5 Consignes générales de sécurité: LIRE LES CONSIGNES DE SECURITE Entretien: Ces produits ne peuvent pas être réparés par l’utilisateur. Seuls, TDK-Lambda UK LTD et ses agents agréés sont autorisés à effectuer des réparations. Composants critiques: Ces produits ne doivent pas être utilisés en tant que composants critiques dans des systèmes de commande nucléaire, dans des systèmes de sauvetage ou dans des équipements utilisés dans des environnements dangereux,...
  • Seite 6 Un fusible interne protège le module et ne doit pas être remplacé par l'utilisateur. En cas de défaut interne, le module doit être renvoyé à TDK-Lambda UK LTD ou l'un de ses agents agréés. AVERTISSEMENT: Ces produits sont des produits Classe 1 et donc doivent être raccordés à une terre fiable et installés par un professionnel en respectant les réglementations de câblage électrique en vigueur et les normes de...
  • Seite 7 Manutenzione: Il cliente non può eseguire alcuna manutenzione su questi prodotti. L'esecuzione delle eventuali riparazioni è consentita solo a TDK-Lambda UK LTD e ai suoi agenti autorizzati. Componenti critici: Non si autorizza l'uso di questi prodotti come componenti critici all'interno di sistemi di controllo nucleari, sistemi necessari alla sopravvivenza o apparecchiature destinate all'impiego in ambienti pericolosi, senza l'esplicita approvazione scritta dell'Amministratore Delegato di TDK-Lambda EMEA.
  • Seite 8 Un fusibile interno protegge l'unità e non deve essere sostituito dall'utente. Nell'eventualità di un difetto interno, restituire l'unità a TDK-Lambda UK LTD o a uno dei suoi agenti autorizzati. AVERTIMENTO: Questi prodotti sono di Classe 1 e come tali devono essere messi a terra in modo affidabile e installati in modo professionale, nel rispetto dei regolamenti vigenti in ambito locale in materia di collegamenti elettrici e nelle norme di sicurezza in essi contemplati.
  • Seite 9 Instrucciones generales de seguridad: LEA LAS INSTRUCCIONES DE SEGURIDAD Servicio: Estos productos no pueden ser reparados por los clientes. TDK-Lambda UK LTD. y sus agentes autorizados son los únicos que pueden llevar a cabo las reparaciones. Componentes fundamentales: Estos productos no pueden ser utilizados como componentes fundamentales en sistemas de control nuclear, sistemas de soporte vital o equipos a utilizar en entornos peligrosos sin el consentimiento expreso por escrito del Director General de TDK-Lambda EMEA.
  • Seite 10 Un fusible interno protege la unidad y este no debe ser nunca reemplazado por el usuario. En caso de existir algún defecto interno, la unidad debe ser enviada a TDK-Lambda UK LTD o a uno de sus agentes autorizados. AVISO: Estos productos son de Clase 1 y, por tanto, se deben conectar de forma fiable a tierra y sólo pueden ser instalados por profesionales de acuerdo con con las regulaciones sobre cableados eléctricos y las normas de...
  • Seite 11 Instruções gerais de segurança: LEIA AS INSTRUÇÕES DE SEGURANÇA Manutenção: Estes produtos não são podem ser submetidos a manutenção por parte do cliente. Apenas a TDK-Lambda UK LTD e os seus agentes autorizados têm permissão para realizar reparações. Componentes essenciais: Não é...
  • Seite 12 Existe um fusível interno que protege a unidade e que não deve ser substituído pelo utilizador. Em caso de defeito interno, a unidade deve ser devolvida à TDK-Lambda UK LTD ou a um dos seus agentes autorizados. AVISO: Estes produtos pertencem à Classe 1, devendo assim ser ligados à terra de forma fiável e instalado por profissionais, de acordo com os regulamentos locais vigentes em relação a cablagens eléctricas e as normas de...
  • Seite 13 Special Instructions for IEC/EN/UL/CSA 61010-1 If the earth terminal of the NV175 PSU is connected to the main incoming earth conductor of the end equipment, the installer must cover the NV175 earth symbol with a label bearing the earth symbol of IEC60417-5019.
  • Seite 14 IEC/EN/UL 61010-1, CAN/CSA 22.2 No. 61010-1-12 IEC/EN62368-1 – CE and UKCA mark. CE marking when applied to any NV175 product, indicates compliance with the Low Voltage Directive in that it complies with EN62368-1 and with the RoHS Directive. UKCA marking when applied to any NV175 product indicates compliance with the Electrical Equipment (Safety) Regulations 2016 in that it complies with EN62368-1 and with the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.
  • Seite 15 NV175 Instruction Manual PRODUCTS COVERED Unit Configuration Code: NVx-abcde-f-g-h-ijk where: x = 1 for 175 Number of Outputs : 1, 2, 3 or 4 Channel 1 Output Voltage†: 5, T, F, E or G Channel 2 Output Voltage†: 1 , 2, 3, 5, 5L, 7 or 0 Channel 3 Output Voltage†: 3L, 5L, 7, TL, FL, T, F, G followed by Y for negative output or 0...
  • Seite 16 Variations and limitations of use: 1. All NV175 PSUs can output 180W except 5V channel 1 models which can output 175W. 2. Units with channel 1 T and G outputs (no other channels fitted) have a peak power output of 200W including the...
  • Seite 17 Channel 2 cannot be fitted Cannot be global option variants 4. There is no –F, -M, -MR or –I options for the NV175 –H or –HR high altitude models 5. Fan versions: Channel 1 with G output, 25V maximum with 5V channel 2 maximum output current of 7A.
  • Seite 18 NV175 Instruction Manual Capacitive Loads Outputs on NV175 are designed for use with capacitive loads up to the value shown in the table below. Applications where a discharged capacitor is switched onto the power supply output create additional loading for which a non standard product may be required.
  • Seite 19 NV175 Instruction Manual COMPONENTS TO BE MONITORED Base board (NV175 –Nx versions) Page 19 of 27 17159 issue 32, October 2021...
  • Seite 20 NV175 Instruction Manual Base board (NV175 Narrow and -M & -MR versions) Page 20 of 27 17159 issue 32, October 2021...
  • Seite 21 NV175 Instruction Manual Control board SMA 1 channel 2 board SMA 2 channel 3 board (SMA 3 channel 4 THV, FHV) SMA 3 channel 4 board (SMA 1 channel 2 5L, SMA 2 channel 3 xL, where x = 3, 5, T or F)
  • Seite 22 NV175 Instruction Manual Open Frame Version with Vertical Output Connector Page 22 of 27 17159 issue 32, October 2021...
  • Seite 23 NV175 Instruction Manual Cased Version with Vertical Output Connector NOTES 1 ALL CUSTOMERFIXINGS M3 MAXIMUM PENETRATION 4.5mm MAXIMUM TORQUE 0.5-0.6Nm 2 ALL TOLERANCES +/-0.5mm Page 23 of 27 17159 issue 32, October 2021...
  • Seite 24 NV175 Instruction Manual Open Frame Version with Right Angled Output Connector (–R & -MR) Page 24 of 27 17159 issue 32, October 2021...
  • Seite 25 NV175 Instruction Manual Cased Version with R Output Connector NOTES 1 ALL CUSTOMERFIXINGS M3 MAXIMUM PENETRATION 4.5mm MAXIMUM TORQUE 0.5-0.6Nm 2 ALL TOLERANCES +/-0.5mm Page 25 of 27 17159 issue 32, October 2021...
  • Seite 26 NV175 Instruction Manual Fan/IEC version chassis layout with vertical output connector Page 26 of 27 17159 issue 32, October 2021...
  • Seite 27 NV175 Instruction Manual Fan/IEC version chassis layout with right angle connector TDK-Lambda UK Ltd Kingsley Avenue, Ilfracombe Devon, EX34 8ES Telephone - Sales and Service +44 (0)1271 856666 Head Office and Works +44 (0)1271 856600 Facsimile +44 (0)1271 864894 WEBSITE: www.uk.tdk-lambda.com...