GB
• Do not expose the product to direct sun and shield it from extreme heat!
• Do not bend using force!
• To avoid damage, do not bend or knot cables over sharp edges or corners!
• Push the ground spike into firm ground (stability must be ensured) no further than the marking (figure a).
• Please note, that electrical installations operating outside must be equipped with an RCD switch with a
maximum residual current of 30mA (protection of people).
• The sealing ring must be intact.
• Please note that it is not permitted to rotate the radiator joints more than 360°, otherwise the cable
may be damaged. To prevent over-rotation, the screws at the joints must be tightened.
• Before replacing the light bulb, pull out the mains socket, wait for 10 minutes until the light bulb has cooled
down. Danger of burns. Screw the new and clean lamp into the lamp socket. When screwing in, ensure that the
gasket is straight on the luminaire housing. Check that the gasket is fully and completely attached to the new
screwed lamp, to guarantee splash water protection (IP44).
• The product must not be used in depressions in the ground because otherwise water might ingress. Danger of
flooding.
• Check the lead and seal ring regularly for damage. In case of defects in the lead and/or seal ring, have
them replaced by a qualified electrician.
SCOPE OF DELIVERY
Check the delivery for completeness and perfect condition.
In the case of missing parts or damage:
• do not mount the unit!
• do not put the unit into operation!
• make a complaint to the supplier.
The deliver consists of:
• Product
• Mounting material (180mm ground spike )
• Instructions

TECHNICAL DATA

• Output: max. 80W (SPG-211) / max. 2x80W (SPG-212)
• Illuminant: E27 PAR38 only approved for IP44 application (exclusive)
• Nominal values: 230V~; 50Hz
• IP protection class: IP44, only when sealing ring is intact and luminant PAR38 is used
• Protection class: II, safety insulated (S8)
• Ambient temperature: -10°C - +40°C
• Dimensions W x H x D: 170 x 140 x 80mm (without ground spike)
• Weight (without illuminant): 406g (SPG-211) / 731g (SPG-212)
• Supply line: 1,4m H05RN-F 2x1mm²
INSTALLATION
• Please refer to the drawings for the installation steps.
CLEANING
• Disconnect the product from the power supply and secure the circuit from being switched on again.
• Allow the luminaire to cool down sufficiently!
• Before cleaning, unplug the product from the power point or disconnect it from the mains supply!
• Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent if required. Do not use cleaners that
contain abrasives or solvents.
MAINTENANCE
• Remove all dirt from the housing or protective panel immediately, as this can lead to overheating.
WEEE DISPOSAL INFORMATION
According to the European regulations, used electrical and electronic equipment may no longer be put out into
unsorted rubbish. The symbol on the wheeled rubbish bin points out the necessity for separated collection. Help
us to protect the environment and ensure that this unit is put out in the appropriate systems for separate collection
once you do not use it any longer. DIRECTIVE OF THE EUOROPEAN PARLIAMENT AND COUNCIL of 4th July 2012
concerning used electrical and electronic equipment (S9).
10
SERVICE
If you have any questions concerning our products or a complaint, then please go to www.rev.de to find out how
to make contact or how to organise a return. Alternatively, send an email to service@rev.de. We'd like to point out
that we are unable to process any shipments which do not have a return number and will not accept them.
GB