Herunterladen Diese Seite drucken

NA-DE 10951 Kurzanleitung Seite 2

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10951-10952
CEILING TYPE LED SENSORLIGHT
WITH HF MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take out the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 15 - 20 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close the objects as heaters, fans, refrigerators and ovens etc,
• It can cause the device operate inaccurately if there is moving objects in the coverage area.
SPECIFICATIONS
Operating voltage
Detection angle
Mounting height
Detection range
Time settings
Lighting load
Emergency Lighting Load
Battery type
3x1.2V 1000 mAh N -CD AAA
Battery opr. time
Protection class
Opr. temperature
Power consumption (Active/Stand-by)
SETTING
(1)
(1) Detection Range Setting
SENSE adjustment is used to set the detection range. Also the movement can effect the detection
range. increase the sense adjustment will raise the detection range, also decrease the sense
adjustment will reduce the detection range.
(2) Time setting
Light ON time can be adjusted continuously from "10 sec. ± 1 sec. / 30 min. ± 1 min." If you turn
the knob counter clockwise device will operate at minimum time. (10 seconds)
Control dial set to - = Shortest time (10 sec. ± 1 sec.)
Control dial set to + = Longest time (30 min. ± 1 min.)
(3) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux. If you turn the knob
counter clockwise device will operate at dark.
Control dial set + = daylight operation approx. 2000 lux.
Control dial set - = night-time operation approx. 2 lux.
NOTE: Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion
by this period.
www.dmyeoa.com.tr
Emek Mah. Ordu Cad. No:. 49, 34785 Sancaktepe/İSTANBUL - TÜRKİYE
10951
230-240V~ 50/60 Hz
360°
2.8 m.
3m / 9m. (adjustable)
10 sec. ± 1 sec. / 30 min. ± 1 min.
730 lm
42 lm
3 Hours
IP20
CLASS II
-20°C ~ +40°C
11.8W / 3.15W
10.9W / 1.6W
(2)
(3)
DETECTING RANGE
SYSTEM COMPONENTS
(a) Glass
(b) Body
(c) Mounting hole
(d) Terminals
(e) Battery socket
(f) HF motion sensor module
(g) Cable hole
(h) Setting trimpot
10952
Fix the body (b) to ceiling as parallel shown by (c). Pass the cable through the hole (g). Then
connect the line cable to the terminal shown by (d). Set the trimpots (h) according to the
environment conditions. Fix the glass(a) to the body by turning clockwise.
-
-
-
TROUBLESHOOTING
MALFUNCTION
• LEDs are off
• There is no
electricity on the
device
• LEDs are on
Continuously
• Changing detection
area in device
• LEDs do not turn
ON
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded. Claims under the warranty will only be
accepted if the unit is sent fully assembled and well packed complete with a brief description
of the fault, a receipt or invoice (date of purchase and dealer's stamp) to the appropriate Service
Center.
60598-2-1
Complies with ROHS Regulation
Directive 2002/95/EC
L
(L) = Line conductor
N
(N) = Neutral conductor
360°
4.5 m.
4.5 m.
9 m.
(b)
(a)
(c)
CAUSE
• Day light adjustment set to
• Control daylight setting and
night-time mode during daytime
re-adjust
operate
• LEDs are defected
• Call technical servise
• Power switch off or no electricity
• Check the electricity and power
on.
• Change the fuse.
• Fuse faulty
• Fuse switch off or fuse faulty
• Check the fuse if necessary use
a new fuse.
• Connection faulty.
• Check the connection cables.
• Check the detection area.
• Continuously movement in
detection area
• Avert it is being detection.
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
• Change detection area, change
site of installation.
trees & bushes or open windows in
detection zone.
• Sudden temperature changes due
• Change site of installation or
keep the reasons away.
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
• Change site of installation.
• There is energy
• Turn of the energy
• No movement
• Make it see the movement
• Battery is low
• Charge battery / Change battery
GB
(c)
(e)
(f)
(g)
(h)
(c)
(d)
SOLUTION

Werbung

loading

Diese Anleitung auch für:

10952