4
Automatic and manual function
With this connection, the light fixture
can be operated in automatic or manual
mode, also called forced or continuous
operation. You can install your light fixture
on a "single switch" to switch on/off ma-
nually (temporarily, for a dinner party on
the terrace for example) instead of using
the detector.
c. Adjustment
• TIME: timer adjustment. You can adjust the time
the light stays on after detecting a movement from
10sec ± 3sec to 7min ± 2min.
• LUX: light level adjustment.
You can adjust the level of darkness from
which your fixture will be triggered.
In general, 3 LUX is the night value
and 2,000 LUX is the day value.
: triggering day and night
: night-only triggering
: triggering at dusk.
A
red
rouge
blue
bleu
brown
marron
Continuous operation
Interrupteur
switch
marche continue
220/240V
TIME
LUX
+
-
11