1. Function and features
• The pressure sensor detects the system pressure,
• shows the current system pressure on its display (indication as
from 1% to 105% of the value of the measuring range),
• and generates 1 output signal according to the set output
configuration.
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
Applications
Type of pressure: relative pressure
Order no.
PN5xx0/PE5xx0
PN5xx1/PE5xx1
PN5xx2/PE5xx2
PN5xx3/PE5xx3
PN5xx4/PE5xx4
PN5xx6/PE5xx6
PN5xx7/PE5xx7
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
For gaseous media the application is limited to max. 25 bar.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
Indication of the current system pressure as from 1% of the
value of the measuring range. Display "0" does not mean that
the system is free of pressure!
Measuring
range
0 ... 400 bar
0 ... 250 bar
0 ... 100 bar
0 ... 25 bar
0 ... 10 bar
0 ... 2.5 bar
0 ... 1 bar
Permissible
overl. pressure
600 bar
400 bar
300 bar
100 bar
50 bar
20 bar
10 bar
Bursting
pressure
1000 bar
850 bar
650 bar
350 bar
150 bar
50 bar
30 bar
15