1. Insert the suction hose (2) into the suction hose
connector;
▪ To vacuum, fit the hose in the suction hose connector
(3);
▪ To blow, fit the hose in the air outlet connector.
2. Spin it clockwise to fit the hose;
3. Check if the hose is well tightened;
4. Insert the suction pipe (1) into the hose fitting;
To remove the suction hose:
5. Spin it counter clockwise and remove the hose.
Never operate the vacuum cleaner without having
the HEPA filter installed. The HEPA filter prevents ash
and dust intake to the engine, thus preventing breakdowns.
1. Unlock the cover fasteners (8) and remove the cover (4);
2. Install the HEPA filter (11) in the engine base (13);
3. Tighten the fixing screw (10) of the HEPA filter;
4. When the HEPA filter is installed and well tightened, the
safety switch (12) is pressed;
5. Place the cover and lock the cover fasteners.
The vacuum cleaner was designed for household use to
vacuum up ash and dry debris, not for use in industrial
environments.
Never use the appliance for vacuuming:
▪ Water or any other liquid;
▪ Dusts hazardous to health (dust class L, M, H);
▪ Hot or flammable objects with temperatures above 50°C.
At temperatures over 50°C there is a danger of
combustion;
▪ Dust or combustible/explosive liquids;
▪ Soot.
Before vacuuming the ash, you should take a few
precautions:
▪ Shake the ash with a metal object to check that the ash
is still hot. Ash or debris that seem to have cooled down
may still be extremely hot inside. Ensure that the ash is
completely extinguished before vacuuming;
▪ During ash vacuuming, permanently check the suction
hose and the vacuum cleaner for heating. In case of
overheating, switch off the appliance immediately and
remove the power cord.
Avoid vacuuming debris and materials that could decrease
airflow and block or clog suction accessories.
Never use the vacuum cleaner if the suction power is too
low. If this happens, check that the tank is full and check
the cleaning condition of the HEPA filter (refer to the
maintenance instructions). Also check if there are any
blockages or clogging in the suction tube.
Make sure the ash tank (9) is completely empty before
you switch on the vacuum cleaner.
1. Set the "ON/OFF" switch (5) to position "I";
To switch off the vacuum cleaner:
2. Set the "ON/OFF" switch to position "0".