BACS Module
Module revision alarm
Revision Alarm Off
reset
BACS Equalizing
Balancing/Equalization
deactivated by
does not take
System
effect for up to 4 days.
BACS Equalizing
Balancing/Equalization
deactivated by
restarted - warning reset
System Off
BACS String
Discharge Current
Current Deviation
difference between
Discharge Alarm
strings too high
BACS String
Discharge Current
Current Deviation
difference between
Discharge Alarm
strings Alarm reset
Off
BACS String
Charge Current
Current Deviation
difference between
Charge Alarm
strings too high
BACS String
Charge Current
Current Deviation
difference between
Charge Alarm Off
strings too high reset
BACS String
Discharge Current
Current Deviation
difference between
Discharge
strings high
Warning
BACS String
Discharge Current
Current Deviation
difference between
Discharge
strings high reset
Warning Off
BACS String
Charge Current
Current Deviation
difference between
Charge Warning
strings high
BACS String
Charge Current
Current Deviation
difference between
Charge Warning
strings high reset
Off
Copyright of the European Union is effective (Copyright EU) (c) 2023 GENEREX Systems GmbH, Hamburg, Germany, All rights reserved
TEL +49(40)22692910 - EMAIL generex@generex.de - WEB www.generex.de (This and all other product datasheets are available for download.)
BACS ATEX Installationsanleitung V2023-09-04
alarm / warning cleared
If the balancing/equalisation does not
show any effect on one or more
modules/batteries, it will be turned off
after some time and this warning is
triggered
alarm / warning cleared
BACS has noticed there is a problem
when string current measurements
deviates compared to other strings during
a discharge cycle.
alarm / warning cleared
BACS has noticed there is a problem
when string current measurements
deviates compared to other strings during
a charge cycle after discharging.
alarm / warning cleared
BACS has noticed an unusual high
current difference within the battery
strings during a discharge cycle.
alarm / warning cleared
BACS has noticed an unusual high
current difference within the battery
strings during a charge cycle.
alarm / warning cleared - no action
For your information.
Check battery health
For your information.
Check Charger and battery string health
For your information.
Check Charger and battery string health
For your information.
Check Charger and battery string health
For your information.
Check Charger and battery string health
For your information.