Operation
The energiser will be on as soon as it is plugged in to the mains power supply and switched on at
the wall or it is connected to a battery.
Fence voltage
The Indicator lights show the voltage at the energiser's Fence output terminal. Each Indicator light
segment represents an increment of approximately 1 kV (1000 V) of output voltage. For example,
if the first eight Indicator light segments are illuminated at each pulse, the output voltage is
approximately 8 kV (8000 V).
Red
1
2
3
Note: If ten Indicator light segments are illuminated, the output voltage may be more than 10 kV
(10,000 V).
If you see only red lights at each pulse and no green lights, your fence line is very heavily loaded,
and you will need to look for faults on the fence line.

Alarm feature

If the energiser detects a sudden increase in the load on the fence, the warning light may flash
( ), the pulse rate may reduce and the warning buzzer could sound for up to 10 minutes.
For example, this may occur:
• if a cutout switch is closed, connecting a heavily loaded section of the fence to the energiser.
• if a branch falls on the fence.
• if the fence or cable connecting energiser to it experiences a sudden short to ground.
• if something becomes entangled in the fence.
20 seconds after the fence becomes heavily loaded, the energiser may increase its output power
to more effectively energise the fence.
When a warning alarm is issued, switch the energiser off, locate and remedy fault then turn the