Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning, Care & Maintenance; Cleaning The Condenser; Technical Specifications - Polar GH130 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
UK
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the interior of the appliance as often as possible.
Do not use abrasive cleaning agents. These can leave harmful residues.
Always wipe dry after cleaning.
A POLAR agent or qualified technician must carry out repairs if required.

Cleaning the Condenser

Periodically cleaning the condenser can extend the life of the appliance. The condenser is located at the
back of the appliance.
Note: Use a soft brush or vacuum cleaner to clean the fins of the condenser, taking care
not to damage the fins.
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns
Condenser blocked with dust
on, but the
Doors are not shut properly
temperature is too
Appliance is located near a heat source
high/low
or air flow to the condenser is being
interrupted
Ambient temperature is too high
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters adjusted
The appliance is
The appliance is touching a neighbouring
unusually loud
object
The appliance has not been installed in a
level or stable position

Technical Specifications

Model
Voltage
GH130
230V 50Hz
GH131
230V 50Hz
Probable Cause
Temperature
Power
Current
Range
280W
1.8A
2°C to 18°C
280W
1.8A
2°C to 18°C
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Clean Condenser
Check doors are shut and seals are not damaged
Move the appliance to a more suitable location
Increase ventilation or move appliance to a cooler
position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Call POLAR agent or qualified Technician
Check installation position and change if necessary
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
223
R134a 140g
223
R134a 140g
Action
Dimensions
Weight
H x W x D (mm)
(kg)
925 x 920 x 540
75
925 x 920 x 535
72

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gh131

Inhaltsverzeichnis