Technical parameters /
Technische Parameter
Supply voltage:
Apparent power:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. switching power DC:
Mechanical service life:
Electrical service life (AC1):
Control
RF command from the transmitter:
Manual control:
Range in open space:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Cross-section of connecting wires (mm
Recommended power cord:
Dimensions:
Weight:
Related standards:
Attention:
The minimum distance between the controller (system unit) and the actuator must not be less
than one centimeter.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
Spannungsversorgung:
Scheinleistung:
Verlustleistung:
Toleranz Spannungsversorgung:
Ausgang
Anzahl Kontakte:
Messstrom:
Schaltstrom:
Spitzenstrom:
Schaltspannung:
Min. Schaltleistung DC:
Mechanische Lebensdauer:
Elektrische Lebensdauer (AC1):
Steuerung
RF Frequenzen der Sender:
Manuelle Steuerung:
Reichweite im Freien:
Andere Daten
Arbeitstemperatur:
Arbeitsposition:
Montage:
Schutzart:
Überspannungskategorie:
Verschmutzungsgrad:
2
):
Querschnitt der Anschlusskabel (mm
Empfohlene Anschlüsse:
Abmessungen:
Gewicht:
Standards:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln | Deutschland | E-mail: elko@elkoep.de | Tel: +49 (0) 221 222 837 80
www.elkoep.com / www.elkoep.de
230 V AC / 50 - 60 Hz
120 V AC / 60Hz
5 VA / cos φ = 0.1
5 VA / cos φ = 0.1
0.6 W
0.6 W
+10 %; -15 %
1 x switching / Umschaltkontakt (AgSnO
12 A / AC1
3000 VA / AC1, 384 W / DC
30 A / < 3 s
250 V AC1 / 24 V DC
500 mW
3x10
0.7x10
868 MHz, 915 MHz, 916 MHz
button / Taste PROG (ON/OFF)
up to / bis zu 200 m
-15 ... + 50 °C
any / beliebig
screws / Schrauben
IP65
III.
2
2
max.1x2.5,max. 2x1.5 / a hollow / mit einem Abstand max.1x2.5
):
CYKY 3x1.5 (CYKY 4x1.5)
136 x 62 x 34 mm
146 g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC) /
EN 60669, EN 300220, EN 301489 Richtlinie RTTE, RG Nr.426/2000 Sgl. (Richtlinie 1999/EG)
Achtung:
Die Entfernung zwischen Sender und Empfänger sollte nicht weniger als 1 cm betragen.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1 s Abstand liegen.
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifi kation, nach dieser
Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott zu
behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle Leitungen,
miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und der Wartung
sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu beachten. Berühren
Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der Sendeleistung des RF-
Signals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude, in dem die Installation
stattfi ndet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind nicht für die Montage in
Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht in Metallschalttafeln und in
Kunststoff -Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des RF-Signals ist dann nicht gegeben.
RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und abgeschirmt werden, die Batterie des
Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung durch eine Steuerungseinheit.
12-24 V AC/DC 50-60Hz
-
0.7 W
)
2
7
5
02-58/2015 Rev.1
6/6