Technical information / Safety instructions
About these instructions
These instructions describe the installation of the sliding door sys-
tem HELM GT-L 80 timber - wall installation. The installation is
shown using the example of a right-opening door. For left-opening
doors, the installation must be carried out in mirror image.
certified according to DIN EN 1527:2013 (200.000 cycles)
ƒ
max. leaf weight: 80 kg
ƒ
leaf thickness: from 30 to 50 mm
ƒ
all dimensions in millimeter
ƒ
For safe and proper use, follow these instructions.
Keep them for future reference.
Important advice to prevent injury to persons and
damage to property
Clean the tread of track
Intended use
The sliding door fittings are only suitable for dry indoor spaces.
ƒ
Open and close hand-operated sliding elements using only
ƒ
the intended door handles and flush pulls.
Do not slam and shove hand-operated sliding elements; slow-
ƒ
ly guide them into the desired position.
Any other use is considered improper and will invalidate all
ƒ
liability and warranty.
Safety instructions
Installation and commissioning may only be carried out by
ƒ
qualified personnel.
Suitable protective clothing must be worn during installation.
ƒ
We recommend the installation to be carried out by two peo-
ƒ
ple.
There is a risk of injury due to moving parts in the sliding area
ƒ
of the door leaf.
Requirements for the wall, ceiling and floor and the fixing ma-
terial
The load bearing capacity of the wall or ceiling must meet sta-
ƒ
tic and dynamic requirements.
The substructure must be permanently capable of bearing
ƒ
loads, flat and plumb (max. tolerance 2 mm per metre).
The fixing material must be suitable for the substructure and
ƒ
meet the static and dynamic requirements. Refer to the tech-
nical instructions for the fixing material.
The fixing material is not included in the scope of delivery.
ƒ
Maintenance
The hardware parts are almost maintenance-free and easy to
clean. The sliding door fittings must be checked regularly for signs
of wear or damage. Damaged systems may not be operated any
longer. Furthermore, all fastening elements such as screws, nuts,
etc. must be checked and a functional test must be carried out. Re-
pair work must be carried out by qualified personnel or specialist
companies. Only original spare parts are to be used.
Cleaning
Do not clean anodized aluminum with acids or other alkaline clea-
ners. Furthermore, scouring powder and steel wool should not be
used for cleaning. Dust, stains and light soiling can be removed
with lukewarm water. Persistent soiling such as gypsum or cement
remnants can be easily removed if you add a few squirts of a con-
ventional wetting agent (like dish washing liquid) to the water. A
small squirt of a wetting agent is sufficient to obtain good results
during cleaning. We explicitly point out that the anodized coating
can be damaged by mortar and lime water. That means it is im-
portant that the bucket with water does not contain any substances
other than a wetting agent.
Disposal
Disassembly of the system is carried out in the reverse order of in-
stallation and must be performed by qualified personnel. The pro-
duct must be disposed of in an environmentally friendly manner.
Refer to the national statutory regulations.