System Safety

The Dragonfly®4 filtration trolley is manufactured with the safety of the operator in mind,
including some key features such as; result in serious personal injury.
Over Pressure
If the water pressure in the Dragonfly®4 system is above the
standard 2.8bar / 40Psi pressure, the pressure switch is activated to
stop the pump over pressurizing
It is important to never open the Dragonfly®4 pump during
operation or whilst under pressure.
Over Heating
If the pump overheats on the Dragonfly®4 system, an activation
switch is triggered and the system will automatically switch off.
Electrical Hazards
Do not use the Dragonfly® in the vicinity of power lines, junction boxes,
power sockets
If the Dragonfly® is used to clean illuminated signs, remember to switch
off the power supply first
Never direct the jet towards people, animals or electrical equipment
Before each use, undertake a visual check on all electrical cables for
damage. Never use the Dragonfly®4 system with a damaged cable.
Mechanical Hazards
When using the Dragonfly® do not place it on the ground or use it as a
support element.
Use only original accessories that come with the Dragonfly®4 system, offering maximum quality and
security. Failure to use original accessories absolves Varitech Systems Ltd, the manufacturer
from all liability.
6
W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

Electrical Specifications and Safety

This applies to all Dragonfly®4 systems.
Electrical connections must be carried out in respect of current legislation (in compliance with the
provisions of the IEC 60364-1 standard) and in accordance with the manufacturer's instructions.
-
Varitech Systems Ltd, the manufacture of Streamline® declines all liability for dam
age to persons, animals or things caused by faulty or incorrect connection.
-
Before connecting the equipment, check that the specification given on the rating plate
corresponds to that of the mains electrical supply.
-
If the equipment is connected via an extension, use cables with an adequate cross section,
never less than 1,5 mmq. The plug and socket must be watertight.
-
The electrical safety of the equipment is guaranteed only when correctly and efficiently
earthed as specified in current electrical safety legislation (in compliance with the
provisions of the IEC 60364-1 standard). This fundamental safety requisite should be
verified. If in doubt, ask a professionally qualified electrician to check the system
thoroughly. It is recommended that the electric supply to this machine should include a
residual current device that will interrupt the supply if the leakage current to earth
exceeds 30 mA for 30ms or a device that will prove the earth circuit.
Varitech Systems Ltd, the manufactures of Streamline®, declines all liability for damage caused by
faulty earthing of the appliance.
-
The equipment can be disconnected from the mains only by unplugging the plug
from the mains socket.
-
When using any electrical appliance, certain fundamental rules should be respected:
Do not touch the appliance with wet hands or feet;
Do not touch the appliance with bare feet or unsuitable clothing;
Do not pull the power cable or appliance itself to unplug the plug
from the mains.