Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman PEM7DW Bedienungsanleitung Seite 7

Kabelloses mini-infrarot-sicherheitssystem - 7 m
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Photoelectric Beam Sensor
2
Wireless Speaker
3
Reflector
4
Power adapter
5
Mounting Bracket & screws
for Sensor
* Not incl.
5. Installation
1.
Please check that the speaker is switched to the "Chime" or "Alarm"
position. (Off=Silent).
2.
Please check that the timer and volume potentiometers are NOT in
their min. Position.
3.
The RED LED will be ON when the beam is properly aligned, if the LED
is OFF please realign the beam
4.
The reflector should be mounted a minimum of 50cm from the sensor
otherwise it will be impossible to align the beam properly.
5.
Make sure the plug of AC/DC adaptor is inserted into the DC9~15V
socket of the speaker
6.
If you have purchased the 4 digits counter (optional PEM7D/C), it
should be connected to the "OUTPUT" of the speaker via the included
10 m cable.
7.
Please use the attached screwdriver in the inner box, Don't use any
other size.
6. Troubleshooting
When problems are encountered, refer to following overview before
contacting your local dealer:
Check that the speaker is set to "CHIME" or "ALARM". "OFF" = silent.
Check that the timer and/or volume are not in the "min." position.
A red LED indicates that the sensor and reflector are properly aligned.
If the LED is off, realign the sensor and reflector. The distance should
be at least 50 cm.
Make sure the adapter and sensor are firmly connected to the speaker.
7. Specifications
Presence detection
Light source
Current consumption
V. 01 – 17/03/2023
PEM7DW
7
Screwdriver for duration and volume
adjustment
8
User manual
9
Carton box
Physical properties
IR led
Electrical data
< 130 mA
7
©Velleman Group nv

Werbung

Inhaltsverzeichnis
loading