Safety advice:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is
a risk of mortal injury for which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced
with standard compliant fuses that have the same nominal value.
4
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
4
Choose a location of installation or mounting which complies to the
protection class IP 54.
4
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by
overheating. Absolutely avoid that cables come near any source of heat
(e.g. radioators, other electrical devices, chimney, etc.).
State of the art
201
6-08-30 Technical changes, design modifications,
errors and misprints are subject to change without prior notice.
Technical specifications:
Downstream
Frequency range
Gain
Attenuation (adjustable in 1 dB steps)
Slope (adjustable in 1 dB steps)
Attenuation (Interstage)
Equalization (Interstage)
Output level
Noise figure
Return loss (with r. p. module)
RF Connectors
Test port input, bi-directional
Test port output, uni-directional
Common
Switching mode power supply
Power consumption (w/o r. p. module)
Dimensions appr.
*with RP module BZU 20-xx
1
CENELEC Raster 42 ch. 60dB IMA
Technical specifications:
BVS 20-46
Downstream
Frequency range
Gain
30 dB
Attenuation (adjustable in 1 dB steps)
Slope (adjustable in 1 dB steps)
Attenuation (Interstage)
Equalization (Interstage)
Output level
Noise figure
Return loss (with r. p. module)
RF Connectors
Test port input, bi-directional
Test port output, uni-directional
Common
Switching mode power supply
Power consumption (w/o r. p. module)
Dimensions appr.
*with RP module BZU 20-xx
1
CENELEC Raster 42 ch. 60dB IMA
Manufacturer
EWR contact adress
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
BVS 20-00
85...1006 MHz
36 dB
BVS 20-00 | 20-46/47
15 dB
15 dB
0/2/4/6 dB
premium-line
0/2/4/6 dB
1
107 dBµV (CSO/CTB )
<8 dB
CATV Amplifiers
³18 dB (-1,5 dB/Okt.)
F
-20dB
Operation Instructions
-20dB
100...240 V~/50...60 Hz
8 W
195 × 90 × 55 mm
BVS 20-47
47/85*...1006 MHz
36 dB
15 dB
15 dB
0/2/4/6 dB
0/2/4/6 dB
1
107 dBµV (CSO/CTB )
<8 dB
³18 dB (-1,5 dB/Okt.)
F
-20dB
-20dB
100...240 V~/50...60 Hz
8 W
195 × 90 × 55 mm