Herunterladen Diese Seite drucken

Directions For Use - InnoStyle MEMPHIS 50 35 GH 26 Montageanleitung

Werbung

Display Screen
The whole handset surface is a button panel. If there is no press within 30 seconds, the screen is locked
and 1/2/3/4/S keys are locked correspondingly, you should press Up or Down key first,it can be used
when the display screen light up.
Display Screen
Display the height value of the desk.
Up & Down Keys
Please keep pressing UP/DOWN key to adjust desk height until you get an optimum height.
Memory Key (1/2/3/4)
After seting memory keys, the desk can lift automatically to memory height.
※ How to set memory mode
Click the "S" key when running to a specific point. The display screen displays "S-" and "-" flashes.
At this time, press "1-4" button to store the position to the corresponding label. the memory height is
successfully saved,Then light press 1/2/3/4, the desk moves to memory height automatically.
Set Key(S)
Press the "S" key when memory bits and internal parameters need to be set.
Initialization
1.
When"RST"is on the display screen, press the"
After hearing the "di" sound and desk frame rebounds, initialization is completed.
(P .S. The button cannot be released during this operation, otherwise the initialization will fail)
2.
Forced initialization: Press the"
the button and press it again for about 5 seconds until hear the "di" sound and desk frame rebound,
and the initialization is completed.
3. Restore the factory settings: When new controller is changed or the parameters need to be restored
to the factory settings, press the"
after about 5 seconds and second "di" sound after 10 seconds. When the display screen shows "RST",
please operate refer to the No.1 item.
Safety Function
When the desktop is on the rise or down, encountered reverse resistance,the desk will rebound.
Handset shows error code and solution
Error code
E1,E6,E7
power fault
nsynchronous height over 1cm
E2
E4
handset fault
E5
Anticollision alert
desktop sloping
E8
E11,E21
Motor defect
E12,E22
controller fault
E14~E17,E24~E27
motor fault
overloading
E18,E28
overtime operation
HOT

DIRECTIONS FOR USE

Up&Down key
Memory key
"button until the desk frame reaches its lowest point.
"button until the desk frame reaches its lowest point, then release
"and"
"buttons simultaneously, you will hear the first "di" sound
Fault cause
change power
Implement the initialization operation 1
Unplug and replug the cable of hand set
Rebound reminder , normal condition
check the desktop
inspect the motor wire
Exchange the controller
change motor
reduce the loading
Automatic recovery after
stop using for 20 minutes
10
Set key
Solution

Werbung

loading