16 /48 Bosch Rexroth AG | Electric Drives and Controls

6 SE312 Control Signals

Impermissible assignments: SMeth can-
not be used. SMpdp, SMibs and SMser
can each be used once only.
For safety and EMC reasons, close off slots
that are not occupied by Rexroth interface
modules with BP302 dummy panels, order
no. 3 608 871 392.
3 Min
Insert the modules into the SE312 tightening
controller from the front and secure them with
bolts against unintended loosening.
Before inserting the in-
terface modules, the
system boxes or
BT300 card rack must
be switched to neutral
and a discharging time
of ≥ 3 minutes must be
taken into account.
SE312 | 3 609 929 984/1.0
6
SE312 Control Signals
6.1
Tightening cell
A tightening cell is defined as the installed
hardware for at least one tightening channel
and at least one data interface for communi-
cation with the operating or evaluation pro-
gram or the superior controller. This includes
the corresponding tightening programs and
tightening applications.
A tightening channel is controlled by an
SE312 tightening controller. The KE310 or
KE312 and SE312 communicate with each
other via an internal bus system.
Up to 48 tightening programs can be stored
in a tightening controller. Only 1 tightening
program can be started at a time.
6.2
Control signals
The tightening cell communicates with the
superior controller via control signals. A PLC
assignment table determines which control
signals are assigned to the inputs/outputs.
The inputs/outputs are assigned in the
BS300 operating program.
For more information, refer to:
– the online guide in the operating program
(programming the assignment table),
– the system documentation, chapter 5
"Control signals" (3 609 929 918) (signal
description, sequence examples, and
chronological sequences).