3.7.4
Information on problems
i
Heed the information given in Section 2.4 in the event
of Bluetooth transmission problems during exhaust
gas measurement.
No communication between BEA 060 and PC/Laptop
Possible causes
Action to be taken
No power supply
Check whether the BEA 060 is being
supplied with voltage (power supply unit
or vehicle battery).
BEA 060 not
1. Start CDC:
active or incorrectly
"Start >> All programs >> Bosch >>
configured.
Diagnostics >> Central Device Commu-
nication" or click onto "
bar with the left mouse key.
2. Check type of connection in CDC:
"Settings >> Device interfaces",
Group:
Device type:
Connection:
Problem with
Bluetooth Manager symbol
Bluetooth link or no
1. Reduce distance between Bluetooth
link (e.g. following
USB adapter and BEA 060.
PC / Laptop stand-
2. If the Bluetooth USB adapter is to be
by mode).
used at various PC/Laptop USB ports,
Bluetooth driver installation must be
performed at each USB port.
3. Perform Bluetooth driver initialization
if the Bluetooth connection is not OK
on testing (refer to Section 3.6.4).
4. Unplug the Bluetooth USB adapter and
plug in again or re-boot the PC/Laptop.
No Bluetooth USB
1. Plug in Bluetooth USB adapter.
adapter.
2. Re-start exhaust gas measurement.
3.8

Functional description

The BEA 060 is used to measure the exhaust gas com-
ponents CO, HC, CO
, O
2
2
ted). The excess air factor (Lambda) is calculated on
the basis of the gas values measured.
The non-dispersive infrared method (NDIR – non-disper-
sive infrared spectroscopy) is employed for measuring
the CO, CO
and HC components. The oxygen is deter-
2
mined using a sensor with electro-chemical action.
Warm-up time
The BEA 060 warm-up time is approx. 1 minute.
Measurements cannot be taken during this period.
Robert Bosch GmbH
" in the task
GAM
BEA 060
USB / BTB (Bluetooth)
white.
and NO (NO can be retrofit-
Zero calibration at the start of exhaust gas
measurement
After switching on the pump, the zero point of the
analysis system is automatically calibrated (duration
30 seconds) with ambient air (zero gas).
Zero calibration during exhaust gas measurement
Following the start of exhaust gas measurement, the
BEA 060 automatically implements a system check with
ambient air at irregular intervals (the oxygen measure-
ment drift is monitored and re-adjusted if necessary).
To perform the system check, the BEA 060 switches
a solenoid valve to ambient air. The system is flushed
with zero gas for 30 seconds. An activated charcoal
filter removes the hydrocarbons from the ambient air
drawn in.
Excess air factor measurement
The BEA 060 calculates the excess air factor (Lambda)
from the measured HC, CO, CO
tions.
Precise oxygen measurement is important for Lambda
calculation. Lambda calculation and oxygen measure-
ment must be activated for this purpose.
The Lambda value is calculated with the aid of the
Brettschneider formula:
[
]
CO
H
[
]
[ ]
CO
+
+
O
+
CV
x
2
2
4
2
λ
=
H
O
CV
CV
1
+
x
4
2
[] Concentration in % by vol, also for HC
K
Conversion factor for HC from NDIR to FID (value 8)
1
Hcv Hydrogen/carbon ratio in the fuel
(typically 1.7261) *
Ocv Oxygen/carbon ratio in the fuel
(typically 0.0175) *
*
Depending on the fuel used.
Oxygen measurement
The BEA 060 is equipped with an O
sor is a wearing part.
The oxygen measurement is automatically compared to
the air oxygen content of 20.9 % by vol and is required
for Lambda calculation.
| BEA 060 | 23
and oxygen concentra-
2
[
]
O
3 5
,
CV
(
[
] [
x
CO
+
CO
2
[
]
CO
2
3 5
,
+
CO
2
(
)
[
] [
]
[ ]
CO
+
CO
+
K x HC
2
1
sensor. The O
2
2
|
1 689 989 112
2016-05-12