Herunterladen Inhalt Inhalt Diese Seite drucken

Error Code - Overview - Siemens VDO MTCO 1324 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Error code - Overview

Displayed message
(Time is flashing)
(Colon is not flashing)
© Siemens VDO Automotive AG
Code
Meaning / measure
9 0 5 3
= • The MTCO 1324 has automatically changed over
to the beginning or the end of the daylight saving
time,
• or the time has been adjusted with the chart
inserted.
or
Note: update the chart carrier settings,
➥ see page 34.
9 0 6 4
= Error during chart carrier settings update
Update the chart carrier settings once again,
➥ see page 34.
9 0 6 4
= Error in the driving mechanism of the chart carrier
Check whether the charts have been correctly
inserted.
A 0 5 0
= Trip without driver 1 chart
(Error code cannot be found in the error memory.)
Insert driver 1 chart.
9 0 5 1
=
Driver 1 chart is missing
9 0 5 2
=
Driver 2 chart is missing
(This message will appear when switching from
, for example, while the chart is missing.)
Insert chart(s).
9 0 0 A
= Error during CAN transmission
9 0 0 B
A 0 0 C
= Internal error
9 0 0 F
= Keypad error, key pressed too long or blocked
9 0 1 0
= LCD error (display)
9 0 6 0
= Error at the drawer
Start the ejection procedure and close the dra-
wer again afterwards.
➥ To be continued on the next page
to
33