Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha 2009 TT-R125 Wartungs-Handbuch Seite 224

Inhaltsverzeichnis

Werbung

BATTERY INSPECTION AND CHARGING
(TT-R125E/TT-R125LWE)
• Before removing the battery charger lead
clips from the battery terminals, be sure
to turn off the battery charger.
• Make sure the battery charger lead clips
are in full contact with the battery terminal
and that they are not shorted. A corroded
battery charger lead clip may generate
heat in the contact area and a weak clip
spring may cause sparks.
• If the battery becomes hot to the touch at
any time during the charging process,
disconnect the battery charger and let the
battery cool before reconnecting it. Hot
batteries can explode!
• As shown in the following illustration, the
open-circuit voltage of an MF battery
stabilizes about 30 minutes after charging
has been completed. Therefore, wait 30
minutes after charging is completed
before measuring the open-circuit voltage.
3-38
INSP
ADJ

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis