11. Troubleshooting
The motor does not start
The pump is operating but
does not deliver
Insufficient flow rate
12. Disposal
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
13. Technical data
Power supply ....................................................... 230 V/AC, 50 Hz
Power consumption ............................................. 1100 W
Fluid quantity ....................................................... max. 15000 l/h
Delivery height ..................................................... max. 9.5 m
Water temperature ............................................... max. 35 ºC
Immersion depth .................................................. max. 8 m
Size of solid particles ........................................... max. 35 mm
Protection class ................................................... IPX8
Dimensions (Ø x H) ............................................. 170 x 360 mm
Weight ................................................................. 6 kg
Connection .......................................................... 1" - 1½"
Cable length ........................................................ 11 m
20
• There is no power
• Temperature monitor has switched off
because the impeller is blocked
• Air in the bell
• Suction base clogged
• Max. discharge height exceeded
• Strainer dirty
• Decreased pump performance
• Check the connections and voltage
• Allow the pump to cool, dismantle it
and clean it
• Turn the intake opening of the pump
under water and allow the air to
escape
• Clean the suction base
• Check the discharge height
• Clean the strainer
• Clean the pump, remove debris