Herunterladen Diese Seite drucken

Duravit SensoWash 254459-Serie Montageanleitung Seite 10

Wand-wc + montageset für vorwandelemente mit leerrohr
Vorschau ausblenden Andere Handbücher für SensoWash 254459-Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Power supply
6..... .. 2 .. ....
6..... .. 1 .. ....
Max. rated power
Circuit breaker
RCCB
Protection type
Protection class
Position of electrical connection
180 mm
7 1/8"
90 mm
3 1/2"
Pre-Installation
DANGER
Risk of fatal electric shock
> Disconnect electrical components from the
power supply before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being
switched on accidentally.
> Lay a permanent power supply line:
• Please observe the position of the
electrical connection
• Leave at least 800 mm (31½") of feed
cable exposed
> Install circuit breaker
• Connect a separate upstream circuit
breaker
• Connect an upstream residual current
device (RCD) separating all poles
10
56918_MAL_SeWa_WWC+Montageset#100691_100730/19.11.5
220 – 240 V 50/60 Hz
100 – 120 V 50/60 Hz
1.65 kW
I
 = 16 A
N
I
 = 30 mA
N
IP X4
1
90 mm
3 1/2"
+
Lay a permanent power supply line
10
45
> Leave at least 800 mm (31½") of feed cable
exposed
+
Connecting the cable
38
72
> Please observe the L, N and PE conductors.
+
Installing junction box
40
74
> Fix the junction box in the Wall-mounted WC
in the designated place.

Werbung

loading