SAFETY NOTES AND OPERATION
Please note the included General Safety Notes and the
following safety notes to avoid malfunctions, damage or
physical injury:
▪ Please read this manual carefully and use the device only
according to this manual.
▪ Dispose of used packaging material carefully or store it out of the
reach of children. There is a danger of suffocation!
▪ To prevent accidents please mount the tap column only on a tilt resistant
and firm foundation which is able to take a load such as stone slabs,
concrete base. Use screws and dowel pins which are adapted for the used
foundation.
▪ Do not use the tap column to deliver drink water.
Application
▪ This column is only intended for use with water. Do not use it to deliver
aggressive chemicals, sewage, acidic or flammable liquids as well as abrasive
substances.
▪ Water contaminated by gravel, silt, sand or similar material may damage the
column.
Mounting the Column
1. Please keep in mind that the column must be cut off from the water mains
and drained during the frosty season. Provide suitable valves or other
means.
2. Build or install a suitable foundation and put the column on the foundation
and align the holes at the pump base.
3. Mark the holes and drill 4 holes into the foundation at the marked positions
by using a suited drill. The mounting holes on the column are intended for a
screw diameter of 8 mm.
4. Insert dowel pins into the drilled holes in accordance to the
screw size (screws not included). You can connect the
column on a water pipe G ½".
5. Collimate the holes of the flange connection and bolt down
the column with suitable screws.
5