Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTRUCTIONS
Model LJ6VH
Models N4000(LLM) N5000 N6000
Models N4300(LLM) N5300 N6300
Models N4950(LLM) N5450 N6450
Models N5450CS N5000CS
Rev. 6.6 / 10-16 Instruction Sheet 32612AM
SPECIFICATIONS
Product Description
Hand cups use vacuum to lift and carry loads, as follows: A manual pump
removes air from between the rubber pad and the contact surface; a red line
on the pump's plunger serves as a vacuum indicator; a check valve allows the
user to repump the cup without removing it from the contact surface; and a
release mechanism allows the cup to disengage completely.
Model
Pad
LJ6VH
LJ6
N4000(LLM),
G0695
N4300(LLM), N4950(LLM)
(VPFS8L)
N5000, N5300, N5450
G0725
N5450CS, N5000CS
VPCS9
N6000, N6300, N6450
G0750
*Maximum Load Capacity includes a 3:1 safety factor and requires the
following: attachment on clean, smooth, nonporous flat surfaces; a minimum
vacuum level of 17½" Hg [-59 kPa]; and a friction coefficient of 1. This rating
is based on tests of new hand cups attached to the upper, horizontal surface
of static objects in ideal conditions. Many factors can reduce the capacity,
including: lifting a load when the cup is attached to a vertical or inclined
surface; or lifting a load that applies leverage to the cup. See
www.WPG.com for more information.
Load and Environmental Conditions
Use the cup on clean, relatively smooth, nonporous surfaces, at temperatures
from 10° to 120° Fahrenheit [-12° to 49° Celsius]. Moisture or contaminants
can reduce the slip resistance of the cup. The red-line indicator may not
perform reliably at elevations above 5000 feet [1524 meters]; see Service.
OPERATION
To Attach
1) Position the hand cup on the contact surface so the red line will be visible
if it should appear while lifting the load. CAUTION: Test the cup for staining
or deformation of load surfaces with light colors or soft coatings.
2) Pump the plunger until the cup attaches completely. When the red line is
hidden, vacuum is sufficient for lifting.
3) Check the plunger frequently to make sure the cup remains securely
attached. If the red line appears while lifting, set down the load immediately
and pump the plunger until the red line is hidden again (see WARNINGS).
To Release
1) Set the load on a secure support.
2) Pull one of the release tabs (on 6" [15 cm] cups) or press the valve
release lever (on other cups) until the cup disengages completely.
CAUTION: Remove the cup when not in use.
MAINTENANCE
Service
Since aging and wear reduce the capacity of the rubber pad, it should be
P.O. Box 368 · 908 West Main |
1.
90510AM
Handle, Metal
2.
90520AM
Plunger Assembly, Metal
(for LJ6VH, N4950, N5450, N5450CS, N6450)
90154AM
Plunger Assembly, ABS (for N4000, N4300,
N5000, N5300, N6000,N6300)
3.
49486T
Vacuum Pad, 8" Dia., Flat (G0695)
49478T
Vacuum Pad, 8" Dia., Flat, Lipped,
Low-Marking (VPFS8L)
49506T
Vacuum Pad, 9" Dia., Flat (G0725)
49520T
Vacuum Pad, 9" Dia., Concave (VPCS9)
49586T
Vacuum Pad, 10" Dia., Concave (G0750)
4.
90500
Valve Block with Release Lever & Guard
5.
51506
Valve Guard
6.
60024
Air Filter
7.
10002
Screw, 1/4-20 x 1/2"
8.
61552
Check Ball
9.
61514
O-Ring
10.
10008
Screw, 10-32 x 3/8"
11.
Red Line
12.
90151
Handle / Valve Assembly, ABS
13.
61151
Check Valve Retainer
14.
51100
Check Valve
15.
Valve Release Lever
16.
Release Tab
17.
90115
Handle, Vertical
18.
49416T
Vacuum Pad, 6" Dia. (LJ6)
19.
10006
Screw, 10-32 x 5/16"
Not Shown
29312
Pad Cover, 6"
29330
Case, Yellow, 8"
NA
29335
Case, Grey, 8"
29334
Case, Black, 8"
29338
Case, Black, 9"
29342
Case, Black, 10"
Nominal Dia.
Max. Load Capacity*
6" [15 cm]
70 lbs [32 kg]
8" [20 cm]
125 lbs [57 kg]
9" [23 cm]
150 lbs [68 kg]
9" [23 cm]
150 lbs [68 kg]
10" [25 cm]
175 lbs [79 kg]
Laurel, MT 59044 U.S.A. | Toll Free: 1-800-548-7341 Phone: 1-406-628-8231 Fax: 1-406-628-8354
N4000(LLM), N5000 N5000CS N6000
N4300(LLM), N5300 N6300 N4950(LLM), N5450 N5450CS N6450
replaced at least once every 2 years or whenever damage is discovered (see
Inspection).
If the hand cup does not function normally, the cup face may be dirty or the
cup may require service. First clean the cup face according to the directions to
follow. If the condition persists, contact an authorized dealer or visit
www.WPG.com for assistance.
Cleaning
1) Remove the air filter from the cup face.
2) Use a clean sponge or lint-free cloth to apply soapy water or another mild
cleanser to the cup face; see WARNINGS and www.WPG.com for more
information. CAUTION: To prevent liquid from contaminating the pump, hold
the cup face-down or cover the suction hole in the filter recess.
3) Wipe all residue from the cup face.
4) Allow the cup to dry and reinstall the air filter.
Inspection
Examine and test the cup regularly to make sure it does not exhibit the
following faults:
• cuts or damage to sealing edges of rubber pad.
• cracks or dents in handle or pump.
• reappearance of red line soon after attaching cup.
• sluggishness or dramatic changes in pump action.
• excessive glaze or stiffness of rubber pad.
• air filter missing from cup face.
Correct any faults before using the cup (see Service).
Storage
Store the cup in clean, dry condition within its protective carrying case.
WARNINGS
Failure to observe WARNINGS could damage the hand cup or the load, or
cause injury to the user.
• Do not use the cup to lift loads that exceed the Maximum Load Capacity or
the effective capacity (see SPECIFICATIONS).
• Do not use the cup to support a person.
• Do not place the cup face against surfaces which could damage the sealing
edges.
• Avoid conditions that could cause the cup to slip or to disengage
prematurely, such as: contaminants, cuts or scratches in the cup face or
contact surface; applying the cup to porous materials; or applying pressure
against the cup edge.
• Do not use the cup to lift when the red line is visible. If the red line
reappears frequently, discontinue use and see Service.
• Do not allow anything to interfere with free movement of the plunger while
the cup is attached.
• Do not touch the release tabs (on 6" [15 cm] cups) or the valve release
lever (on other cups) while lifting.
• Do not attach 10" [25 cm] diameter cups to thin, fragile materials.
• Do not use harsh chemicals (such as solvents or gasoline) or unauthorized
rubber cleaners and conditioners to clean the cup.
Products are manufactured under an
ISO 9001 quality management system.
LJ6VH
R
S
S
8

Werbung

loading

Inhaltszusammenfassung für WOOD'S POWR-GRIP LJ6VH

  • Seite 1 90510AM Handle, Metal N4000(LLM), N5000 N5000CS N6000 LJ6VH 90520AM Plunger Assembly, Metal (for LJ6VH, N4950, N5450, N5450CS, N6450) 90154AM Plunger Assembly, ABS (for N4000, N4300, N5000, N5300, N6000,N6300) 49486T Vacuum Pad, 8" Dia., Flat (G0695) 49478T Vacuum Pad, 8" Dia., Flat, Lipped,...
  • Seite 2 90510AM Mango, metal N4000(LLM), N5000 N5000CS N6000 LJ6VH 90520AM Conjunto de émbolo, metal (para LJ6VH, N4950, N5450, N5450CS, N6450) 90154AM Conjunto de émbolo, A.B.S. (para N4000, N4300, N5000, N5300, N6000,N6300) 49486T Disco de goma, diá. de 20 cm, plana (G0695) 49478T Disco de goma, diá.
  • Seite 3 1. 90510AM Poignée, métal N4000(LLM), N5000 N5000CS N6000 LJ6VH 2. 90520AM Assemblage du piston, métal (pour LJ6VH, N4950, N5450, N5450CS, N6450) 90154AM Assemblage du piston, A.B.S. (pour N4000, N4300, N5000, N5300, N6000,N6300) 3. 49486T Disque à vide, dia. de 20 cm, plat (G0695) 49478T Disque à...
  • Seite 4 90510AM Handgriff, Metall N4000(LLM), N5000 N5000CS N6000 LJ6VH 90520AM Pumpenkolben-Einheit, Metall (für LJ6VH, N4950, N5450, N5450CS, N6450) 90154AM Pumpenkolben-Einheit, ABS (für for N4000, N4300, N5000, N5300, N6000,N6300) 49486T Saugerteller, 20 cm Durchm., flach (G0695) 49478T Saugerteller, 20 cm Durchm., flach, gelippt, zum...

Diese Anleitung auch für:

N4000llmN5000N6000N4300N4300llmN5300 ... Alle anzeigen